A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A validated, sensitive HPLC-MS/MS method for quantification of cis-para-methyl-4-methylaminorex (cis-4,4'-DMAR) in rat and human plasma: application to pharmacokinetic studies in rats. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

4,4'-DMAR is an analogue of the known psychostimulants 4-methylaminorex and aminorex. In the light of reports of deaths associated with its abuse, and the easy access from Internet vendors, the EU Council recently decided on control measures across member states. Here we describe a validated method for measuring plasma levels of cis-4,4'-DMAR, crucial for preclinical studies and analysis in human plasma. Chromatographic separation was done by gradient elution on a Kinetex C18 column with 0.1% formic acid in water and 0.1% formic acid in acetonitrile at 0.2 mL/min. Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring mode monitoring the quantifier transitions m/z 191.4 → m/z 148.3 for cis-4,4'-DMAR and m/z 259.3 → m/z 194.2 for carbamazepine (internal standard). Protein precipitation with 1% of formic acid in acetonitrile was used in cis-4,4'-DMAR extraction from plasma; recovery was high (>93%) with a negligible matrix effect. This method provides an accurate, precise, and sensitive method for cis-4,4'-DMAR quantification in human and rat plasma, following European Medicine Agency guidelines for bioanalytical method validation. Pharmacokinetic studies were conducted in rats. After an intravenous dose of 1 mg/kg, plasma levels declined rapidly (≥80% in 4 h), followed by a slow elimination phase (t of 5.14 ± 0.65 h). Absorption was rapid after intraperitoneal injection (t  = 15 min) with a rapid decline thereafter; C and AUC showed dose-proportionality over the dose range 1-10 mg/kg. This method was successfully applied to investigate pharmacokinetic properties in rats and could be used to quantify cis-4,4'-DMAR levels in human plasma. Copyright © 2016 John Wiley & Sons, Ltd.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dta.2052DOI Listing

Publication Analysis

Top Keywords

human plasma
12
formic acid
12
pharmacokinetic studies
8
plasma levels
8
01% formic
8
acid acetonitrile
8
plasma
7
method
6
cis-44'-dmar
6
validated sensitive
4

Similar Publications