A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The Effects of Air Flow Rates, Secondary Air Inlet Geometry, Fuel Type, and Operating Mode on the Performance of Gasifier Cookstoves. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Development of biomass cookstoves that reduce emissions of CO and PM2.5 by more than 50% and 95%, respectively, compared to a three-stone fire has been promoted as part of efforts to reduce exposure to household air pollution (HAP) among people that cook with solid fuels. Gasifier cookstoves have attracted interest because some have been shown to emit less CO and PM2.5 than other designs. A laboratory test bed and new test procedure were used to investigate the influence of air flow rates, stove geometry, fuel type, and operating mode on gasifier cookstove performance. Power output, CO emissions, PM2.5 emissions, fuel consumption rates, producer gas composition, and fuel bed temperatures were measured. The test bed emitted <41 mg·MJd–1 PM2.5 and <8 g·MJd–1 CO when operating normally with certain prepared fuels, but order of magnitude increases in emission factors were observed for other fuels and during refueling. Changes in operating mode and fuel type also affected the composition of the producer gas entering the secondary combustion zone. Overall, the results suggest that the effects of fuel type and operator behavior on emissions need to be considered, in addition to cookstove design, as part of efforts to reduce exposure to HAP.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.est.6b00440DOI Listing

Publication Analysis

Top Keywords

air flow
8
flow rates
8
geometry fuel
8
fuel type
8
type operating
8
operating mode
8
gasifier cookstoves
8
emissions pm25
8
test bed
8
effects air
4

Similar Publications