A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Enhanced Photoelectrochemical Proximity Assay for Highly Selective Protein Detection in Biological Matrixes. | LitMetric

Enhanced Photoelectrochemical Proximity Assay for Highly Selective Protein Detection in Biological Matrixes.

Anal Chem

State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P.R. China.

Published: August 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This work proposes the first photoelectrochemical proximity assay (PECPA) method via the sensitization of CdTe quantum dots (QDs) on photoelectrochemical response of ITO/TiO2/CdS electrode for highly selective and sensitive detection of proteins. This detection was performed on a sensing interface formed via the hybridization of capture DNA immobilized on ITO/TiO2/CdS electrode with labeled antibody-DNA (DNA-Ab1). Upon the recognition of Ab1 to target protein, the immunocomplex of DNA-Ab1, target, and the detection antibody-DNA (DNA-Ab2) was formed, which led to the proximity hybridization of the DNA in DNA-Ab2, capture DNA, and signal DNA-CdTe QDs, and brought CdTe QDs to the ITO/TiO2/CdS electrode to produce a sensitized photocurrent. The photocurrent intensity increased with the increasing concentration of the specific target protein. Using insulin as a target, this sensitized method showed a detectable range of 10 fM to 10 nM and a detection limit of 3.0 fM without the need of a washing step. It possessed high selectivity and good accuracy for detection of proteins in biological matrixes. This method is extremely flexible and can be extended to varieties of protein targets.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b02740DOI Listing

Publication Analysis

Top Keywords

ito/tio2/cds electrode
12
photoelectrochemical proximity
8
proximity assay
8
highly selective
8
biological matrixes
8
detection proteins
8
capture dna
8
target protein
8
detection
6
enhanced photoelectrochemical
4

Similar Publications