A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

SPECT-CT/VQ versus CTPA for diagnosing pulmonary embolus and other lung pathology: Pre-existing lung disease should not be a contraindication. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Single Photon Emission Computed Tomography-Ventilation-Perfusion (SPECT-VQ) with low-dose CT (SPECT-CT/VQ) has equivalent diagnostic accuracy to CTPA for diagnosing pulmonary embolus (PE) while using lower radiation doses, but is underutilized owing to perceived inaccuracy of scintigraphy in the setting of pre-existing lung disease. This study assesses the accuracy of SPECT-CT/VQ compared with CTPA for the diagnosis of PE, including in patients with pre-existing lung disease.

Methods: Retrospective non-inferiority cohort study of all patients who underwent SPECT-CT/VQ scanning at St Vincent's Hospital, NSW, from June 2012 to November 2013, who also had a CTPA within the same admission and <72 h apart (n = 102).

Results: SPECT-CT/VQ had 100% sensitivity and 94.4% specificity when compared with CTPA. Of the 102 patients, 14 were lung transplant patients, and 27 had other pre-existing lung disease (41/102, 40.2%), with SPECT-CT/VQ having a sensitivity of 100% and specificity of 97.2% in this patient group. Non-inferiority of SPECT-CT/VQ was demonstrated at a significance level of 0.005.

Conclusion: SPECT-CT/VQ has high sensitivity and specificity for diagnosing PE compared with CTPA, even among patients with pre-existing lung disease, with lower radiation doses.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1754-9485.12471DOI Listing

Publication Analysis

Top Keywords

pre-existing lung
12
ctpa diagnosing
8
diagnosing pulmonary
8
pulmonary embolus
8
lung disease
8
spect-ct/vq
4
spect-ct/vq versus
4
ctpa
4
versus ctpa
4
lung
4

Similar Publications