Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study investigated a method for the validation and determination of measurement uncertainty for the simultaneous determination of synthetic phenolic antioxidants (SPAs) such as propyl gallate (PG), octyl gallate (OG), dodecyl gallate (DG), 2,4,5-trihydroxy butyrophenone (THBP), tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT) in edible oils commonly consumed in Korea. The validated method was able to extract SPA residues under the optimized HPLC-UV and LC-MS/MS conditions. Furthermore, the measurement of uncertainty was evaluated based on the precision study. For HPLC-UV analysis, the recoveries of SPAs ranged from 91.4% to 115.9% with relative standard deviations between 0.3% and 11.4%. In addition, the expanded uncertainties of the SPAs ranged from 0.15 to 5.91. These results indicate that the validated method is appropriate for the extraction and determination of SPAs and can be used to verify the safety of edible oil products containing SPAs residues.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2016.06.053DOI Listing

Publication Analysis

Top Keywords

measurement uncertainty
12
method validation
8
uncertainty simultaneous
8
simultaneous determination
8
determination synthetic
8
synthetic phenolic
8
phenolic antioxidants
8
edible oils
8
oils commonly
8
commonly consumed
8

Similar Publications

Most of the United States (US) population resides in cities, where they are subjected to the urban heat island effect. In this study, we develop a method to estimate hourly air temperatures at resolution, improving exposure assessment of US population when compared to existing gridded products. We use an extensive network of personal weather stations to capture the intra-urban variability.

View Article and Find Full Text PDF

Purpose: To evaluate whether AI-assisted ipsilateral tissue matching in digital breast tomosynthesis (DBT) reduces localization errors beyond typical tumor boundaries, particularly for non-expert radiologists. The technology category is deep learning.

Materials And Methods: The study consisted of two parts.

View Article and Find Full Text PDF

Reliable X-ray emission intensities are essential for quantitative material analysis using X-ray spectrometry and for the efficiency calibration of energy-dispersive spectrometers. In order to improve the reliability of data, reference-free measurements were performed to determine X-ray emission intensities, along with their associated uncertainties, for a set of standard radionuclides in the energy range from 5.4 keV to 53.

View Article and Find Full Text PDF

[Ai's use in health care and informed consent].

Cuad Bioet

September 2025

Universidad de A Coruña. Facultad de Derecho, Campus de Elviña, s/n, 15071, A Coruña. 981 167000 ext. 1640

The implications of the use of artificial intelligence (AI) in many areas of human existence compels us to reflect on its ethical relevance. This paper addresses the signification of its use in healthcare for patient informed consent. To this end, it first proposes an understanding of AI, as well as the basis for informed consent.

View Article and Find Full Text PDF

This study explored how meaning in life relates to death and dying anxiety among Israeli civilians during wartime by examining the mediating roles of cognitive age perception and intolerance of uncertainty. A sample of 400 adults (50.5% women; age 47.

View Article and Find Full Text PDF