Computed tomography and magnetic resonance imaging evaluation of pericardial disease.

Quant Imaging Med Surg

Department of Cardiology, Heart of England NHS Trust, Birmingham, UK.

Published: June 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Pericardial diseases are commonly encountered in clinical practice and may present as an isolated process or in association with various systemic conditions. Traditionally transthoracic echocardiography (TTE) has been the method of choice for the evaluation of suspected pericardial disease but increasingly computed tomography (CT) and magnetic resonance imaging (MRI) are also being used as part of a rational multi-modality imaging approach tailored to the specific clinical scenario. This paper reviews the role of CT and MRI across the spectrum of pericardial diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4929280PMC
http://dx.doi.org/10.21037/qims.2016.01.03DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
tomography magnetic
8
magnetic resonance
8
resonance imaging
8
pericardial disease
8
pericardial diseases
8
imaging evaluation
4
pericardial
4
evaluation pericardial
4
disease pericardial
4

Similar Publications

Pancreaticoduodenectomy, also known as the classic Whipple procedure, is the most common surgical treatment for pancreatic adenocarcinoma. Postoperative complications are common and occur in approximately 50% of patients. Prompt detection and management of these complications is vital for improving patient outcomes.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate whether low-dose CT imaging using an Sn filter can provide image quality sufficient for the differential diagnosis of cranial deformities in infants while maintaining an effective dose comparable to that of conventional radiography.

Methods: We calculated the effective dose for both head X-ray imaging and low-dose CT with an Sn filter. Phantom images acquired using a CT scanner equipped with an Sn filter were evaluated for bone suture visibility at various conditions (from 10 mAs to 50 mAs, every 10 mAs) using a 4-point visual grading scale.

View Article and Find Full Text PDF

Purpose: This study presents the dose-based intra-preplan (DIP) method for intracavitary/interstitial brachytherapy (IC/ISBT) in cervical cancer, optimizing catheter configurations based on dose distribution. This study aimed to assess the DIP method's clinical feasibility and efficacy.

Methods And Materials: The DIP method incorporates the implant modeling function and the hybrid inverse planning optimization algorithm in Oncentra Brachy.

View Article and Find Full Text PDF

This study was performed to evaluate the amount of bone implant engagement (BIE) of zygomatic implants (ZIs) at the malar bone level and its correlation with the ZAGA classification (zygoma anatomy-guided approach). One hundred ZIs placed in 32 patients with severe maxillary atrophy using a fully digital protocol were assessed: 80 placed in pairs (40 anterior (AI), 40 posterior (PI)) and 20 as single ZIs (SI). The ZAGA classification was determined preoperatively.

View Article and Find Full Text PDF