Article Abstract

This study describes a simple, rapid, and cost-effective fabrication of PDMS electrophoresis microchips using poly(vinyl acetate) (PVAc) emulsion as photoresist master. High-relief microfluidic structures were defined on poly(vinyl acetate) previously deposited on printed circuit boards surfaces without cleanroom facilities and sophisticated instrumentation. After a UV exposure, channels with heights ranging from 30 to 140 μm were obtained by controlling the emulsion mass deposited on the master surface. The developing stage was performed using water rather than the organic solvents that are applied for conventional masks. The surface morphology was characterized by optical imaging, profilometry, and SEM. Based on the achieved results, the proposed method offers suitable reproducibility for the prototyping of electrophoresis microchips in PDMS. The feasibility of the resulting PDMS electrophoresis chips was successfully demonstrated with the separation of major inorganic cations within 100 s using a contactless conductivity detection system. The separation efficiencies ranged from ca. 67 900 to 125 600 plates/m. Due to the satisfactory performance and simplified instrumentation, we believe this fabrication protocol presents potential to be implemented in any chemical, biochemical, or biological laboratory.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201600209DOI Listing

Publication Analysis

Top Keywords

pdms electrophoresis
12
electrophoresis microchips
12
polyvinyl acetate
12
simple rapid
8
rapid cost-effective
8
cost-effective fabrication
8
fabrication pdms
8
microchips polyvinyl
8
photoresist master
8
pdms
4

Similar Publications

Understanding cells from complex biological samples is vital to understanding cellular biology and medical applications. One evolving tool for cell sorting is the use of microfluidic devices to achieve higher precision and remove the need for labeling cell subpopulations. However, few microfluidic devices have been translated commercially beyond academic research often due to challenges in larger scale fabrication.

View Article and Find Full Text PDF

Bulk methods to fractionate organelles lack the resolution to capture single-cell heterogeneity. While microfluidic approaches attempt to fractionate organelles at the cellular level, they fail to map each organelle back to its cell of origin-crucial for multiomics applications. To address this, we developed VacTrap, a high-throughput microfluidic device for isolating and spatially indexing single nuclei from mammalian cells.

View Article and Find Full Text PDF

Silicone-in-water emulsions have found widespread use as lubricants, water repellants, softeners, binders, antiblocking agents, antislip agents, and defoamers across a diverse range of markets including textiles, coatings, pharmaceuticals, and home and personal care. Stable incorporation of silicone emulsions into formulated products for these applications can be a challenge. This study seeks to enable formulation by investigating the impact of the degree of ethoxylation of sodium lauryl ether sulfate (SLES) surfactants on their ability to displace surfactant stabilizer at the silicone-water interfaces of polydimethylsiloxane (PDMS)-in-water emulsion droplets.

View Article and Find Full Text PDF

Reducing Cathodic Drift during Isoelectric Focusing Using Microscale Immobilized pH Gradient Gels.

Anal Chem

May 2024

The UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley, California 94720, United States.

Microfluidic analytical tools play an important role in miniaturizing targeted proteomic assays for improved detection sensitivity, throughput, and automation. Microfluidic isoelectric focusing (IEF) can resolve proteoforms in lysate from low-to-single cell numbers. However, IEF assays often use carrier ampholytes (CAs) to establish a pH gradient for protein separation, presenting limitations like pH instability in the form of cathodic drift (migration of focused proteins toward the cathode).

View Article and Find Full Text PDF

A new coaxial flow-through probe for electromembrane extraction of methadone from clinical samples on-line coupled to capillary electrophoresis.

Anal Chim Acta

April 2024

Charles University, Third Faculty of Medicine, Department of Hygiene, Ruská 87, 10, 100 00, Prague, Czech Republic. Electronic address:

Background: A new design of a flow-through coaxial electromembrane extraction (EME) probe that can be on-line coupled with CE instrument is described and tested. The supporting base of the probe is a PDMS microchip with T-shaped channels into which two coaxially arranged capillaries for inlet and outlet solutions are inserted. The extraction part of the probe is a porous polypropylene hollow fiber, sealed at one end and modified with nitrophenyloctyl ether (NPOE) extraction fluid.