A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Fabrication of CoTiO3-TiO2 composite films from a heterobimetallic single source precursor for electrochemical sensing of dopamine. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cobalt titanate-titania composite oxide films have been grown on FTO-coated glass substrates using a single-source heterometallic complex [Co2Ti4(μ-O)6(TFA)8(THF)6]·THF () which was obtained in quantitative yield from the reaction of diacetatocobalt(ii) tetrahydrate, tetraisopropoxytitanium(iv), and trifluoroacetic acid from a tetrahydrofuran solution. Physicochemical investigations of complex have been carried out by melting point, FT-IR, thermogravimetric and single-crystal X-ray diffraction analyses. CoTiO3-TiO2 films composed of spherical objects of various sizes have been grown from by aerosol-assisted chemical vapor deposition at different temperatures of 500, 550 and 600 °C. Thin films characterized by XRD, Raman and X-ray photoelectron spectroscopy, scanning electron microscopy, energy-dispersive X-ray analysis have been explored for electrochemical detection of dopamine (DA). The cyclic voltammetry with the CoTiO3-TiO2 electrode showed a DA oxidation peak at +0.215 V while linear sweep voltammetry displayed a detection limit (LoD) of 0.083 μM and a linear concentration range of 20-300 μM for DA. Thus, the CoTiO3-TiO2 electrode is a potential candidate for the sensitive and selective detection of DA.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c6dt01016dDOI Listing

Publication Analysis

Top Keywords

cotio3-tio2 electrode
8
fabrication cotio3-tio2
4
cotio3-tio2 composite
4
films
4
composite films
4
films heterobimetallic
4
heterobimetallic single
4
single source
4
source precursor
4
precursor electrochemical
4

Similar Publications