98%
921
2 minutes
20
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5516133 | PMC |
http://dx.doi.org/10.1111/aos.13053 | DOI Listing |
Cureus
July 2025
Radiation Oncology, Montefiore Medical Center, Bronx, USA.
The use of in vivo dosimetry (IVD) is integral to radiation oncology, particularly for treatments involving custom boluses or superficial electron lesions. In this report, the "myOSLchip" system, comprising beryllium oxide (BeO)-based optically stimulated luminescent chips and hand-held readers, was evaluated for clinical use. Each 4.
View Article and Find Full Text PDFCornea
August 2025
Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico; and.
Purpose: To describe the surgical technique for implantation of a novel flexible, suturable, intrastromal synthetic cornea device.
Methods: This report is a description of a novel surgical technique. Adult patients (≥18 years) with corneal edema who met specific inclusion criteria were enrolled.
ACS Omega
August 2025
Charles L. Brown Department of Electrical and Computer Engineering, University of Virginia (UVA), Charlottesville, Virginia 22904, United States.
We present a compact, multifunctional chemical sensor that seamlessly integrates deep-UV Raman and laser-induced breakdown spectroscopy (LIBS) modalities into a single lightweight hand-held unit. By employing a single 266 nm laser source (1.5 ns pulse width, 10 mW average power) and an integrated autofocus mechanism, this design overcomes the complexities associated with systems that rely on dual or multiple laser wavelengths (e.
View Article and Find Full Text PDFCurr Eye Res
August 2025
Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.
Purpose: The aim of this study was to develop a 3D-printed eye model to simulate measuring intraocular pressure (IOP) as a training device, and to assess the correlation between measured IOP using common clinical techniques and actual internal pressure.
Methods: The IOP eye model was designed using CAD software and printed with a resin stereolithography (SLA) 3D-printer (Formlabs 3B, Formlabs Inc., MA, USA).
ACS Nano
August 2025
Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan.
Passive daytime radiative cooling can mitigate global warming but requires durable and resilient materials for real-world applications. Here, a robust superhydrophobic ZrO-AlO nanofiber (sh-ZANF) membrane is fabricated via electrospinning followed by fluorine-free surface modification. Optically engineered sh-ZANF attains an extremely high solar reflectivity of 97.
View Article and Find Full Text PDF