Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

Arch Pathol Lab Med

From the Department of Laboratory Medicine, Chungnam National University Hospital, Daejeon, South Korea (Drs Lim, Koo, and Kwon); the Department of Laboratory Medicine, Kyungpook National University Hospital, Daegu, South Korea (Dr K.E. Song); the Department of Laboratory Medicine, Seoul National Un

Published: May 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Context: -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices.

Objectives: -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan).

Design: -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania).

Results: -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%.

Conclusions: -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

Download full-text PDF

Source
http://dx.doi.org/10.5858/arpa.2015-0088-OADOI Listing

Publication Analysis

Top Keywords

clinical chemistry
12
chemistry assays
12
chemistry analyzers
8
reference materials
8
abbott architect
8
toshiba 2000fr
8
2000fr neo
8
linearity carryover
8
traceability
5
abbott
5

Similar Publications

Ferroptosis, a controlled cell death influenced by iron-dependent lipid peroxidation, presents potential therapeutic targets for cancer treatment due to its unique molecular pathways and potential drug resistance. Natural compounds, such as polyphenols, flavonoids, terpenoids and alkaloids, can influence ferroptosis via important signalling pathways, such as Nrf2/Keap1, p53, and GPX4. These are promising for combinational therapy due to their ability to cause ferroptotic death in cancer cells, exhibit tumour-specific selectivity and reduce systemic toxicity.

View Article and Find Full Text PDF

Estimation of salivary protectin D1 in periodontitis patients with metabolic syndrome following non-surgical periodontal therapy.

Clin Oral Investig

September 2025

Department of Periodontics, Saveetha Dental College, Saveetha Institute of Medical and Technology Sciences, SIMATS, Saveetha University, Chennai, Tamil Nadu, India.

Objectives: This study aims to assess periodontal and biochemical parameters and evaluate the salivary Protectin D1 levels in periodontitis patients with and without metabolic syndrome after non-surgical periodontal therapy.

Materials And Methods: Forty patients were categorized into two groups: 20 patients in Group P (systemically healthy patients with stage II/III grade B periodontitis) and 20 patients in Group P+MS (patients with stage II/III grade B periodontitis and metabolic syndrome). Parameters including age, gender, height, weight, body mass index, waist circumference, socio-economic status, oral hygiene index (OHI), modified gingival index (MGI), probing pocket depth, clinical attachment levels, fasting blood glucose, HDL-c, total triglycerides, and blood pressure were recorded.

View Article and Find Full Text PDF

Current antithrombotic therapies face dual constraints of bleeding complications and monitoring requirements. Although natural hirudin provides targeted thrombin inhibition, its clinical adoption is hindered by sourcing limitations. This study developed a recombinant hirudin variant HMg (rHMg) with enhanced anticoagulant activity through genetic engineering and established cost-effective large-scale production methods.

View Article and Find Full Text PDF

Autoinjector-based delivery of tranexamic acid provides pharmacokinetic efficacy in a porcine model of uncontrolled hemorrhage.

Injury

August 2025

Institute for Research in Military Medicine (IRMM), Faculty of Medicine, The Hebrew University of Jerusalem and the Israel Defense Forces Medical Corps, Jerusalem, Israel; Department of Military Medicine ("Tzameret"), Faculty of Medicine, The Hebrew University of Jerusalem, and the Israel Defense Fo

Background: Hemorrhage remains the principal cause of death on the battlefield. It is suggested that Tranexamic acid (TXA) can improve survival of severely-bleeding casualties. The intravenous approach is not always available in the pre-hospital setting.

View Article and Find Full Text PDF

Background: In the contemporary era of rapid digital advancement, information security is closely associated with our daily life. From personal information to state secrets, all domains are intricately linked with information. Consequently, the significance of information security has garnered growing attention from an ever-increasing number of individuals.

View Article and Find Full Text PDF