Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Diisocyanates (dNCOs) are low molecular weight chemical sensitizers that react with autologous proteins to produce neoantigens. dNCO-haptenated proteins have been used as immunogens for generation of dNCO-specific antibodies and as antigens to screen for dNCO-specific antibodies in exposed individuals. Detection of dNCO-specific antibodies in exposed individuals for diagnosis of dNCO asthma has been hampered by poor sensitivities of the assay methods in that specific IgE can only be detected in approximately 25% of the dNCO asthmatics. Apart from characterization of the conjugates used for these immunoassays, the choice of the carrier protein and the dNCO used are important parameters that can influence the detection of dNCO-specific antibodies. Human serum albumin (HSA) is the most common carrier protein used for detection of dNCO specific-IgE and -IgG but the immunogenicity and/or antigenicity of other proteins that may be modified by dNCO in vivo is not well documented. In the current study, 2,4-toluene diisocyanate (TDI) and 1,6-hexamethylene diisocyanate (HDI) were reacted with HSA and human hemoglobin (Hb) and the resultant adducts were characterized by (i) HPLC quantification of the diamine produced from acid hydrolysis of the adducts, (ii) 2,4,6-trinitrobenzene sulfonic acid (TNBS) assay to assess extent of cross-linking, (iii) electrophoretic migration in polyacrylamide gels to analyze intra- and inter-molecular cross-linking, and (iv) evaluation of antigenicity using a monoclonal antibody developed previously to TDI conjugated to Keyhole limpet hemocyanin (KLH). Concentration-dependent increases in the amount of dNCO bound to HDI and TDI, cross-linking, migration in gels, and antibody-binding were observed. TDI reactivity with both HSA and Hb was significantly higher than HDI. Hb-TDI antigenicity was approximately 30% that of HSA-TDI. In conclusion, this data suggests that both, the extent of haptenation as well as the degree of cross-linking differs between the two diisocyanate species studied, which may influence their relative immunogenicity and/or antigenicity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4792703PMC
http://dx.doi.org/10.1016/j.jim.2016.02.005DOI Listing

Publication Analysis

Top Keywords

dnco-specific antibodies
16
24-toluene diisocyanate
8
16-hexamethylene diisocyanate
8
human serum
8
serum albumin
8
antibodies exposed
8
exposed individuals
8
detection dnco-specific
8
carrier protein
8
immunogenicity and/or
8

Similar Publications

The influence of diisocyanate antigen preparation methodology on monoclonal and serum antibody recognition.

J Occup Environ Hyg

November 2016

a Allergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown West Virginia.

Exposure to diisocyanates (dNCOs), such as methylene diphenyl diisocyanate (MDI) can cause occupational asthma (OA). Currently, lab tests for dNCO specific IgE are specific, but not sensitive, which limits their utility in diagnosing dNCO asthma. This may be due to variable preparation and poor characterization of the standard antigens utilized in these assays.

View Article and Find Full Text PDF

Diisocyanates (dNCOs) are low molecular weight chemical sensitizers that react with autologous proteins to produce neoantigens. dNCO-haptenated proteins have been used as immunogens for generation of dNCO-specific antibodies and as antigens to screen for dNCO-specific antibodies in exposed individuals. Detection of dNCO-specific antibodies in exposed individuals for diagnosis of dNCO asthma has been hampered by poor sensitivities of the assay methods in that specific IgE can only be detected in approximately 25% of the dNCO asthmatics.

View Article and Find Full Text PDF

Development of sandwich ELISAs for the detection of aromatic diisocyanate adducts.

J Immunol Methods

November 2013

Allergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, WV 26505, USA. Electronic address:

Diisocyanates (dNCOs) are highly reactive low molecular weight chemicals commonly used in the manufacturing industry. Occupational exposures to dNCOs have been shown to elicit allergic sensitization and occupational asthma. Among the most commonly used dNCOs in industry are the aromatic dNCOs, toluene diisocyanate (TDI) and methylene diphenyl diisocyanate (MDI).

View Article and Find Full Text PDF

Protein haptenation by polyurethane industrial intermediate 4,4'-methylene diphenyl diisocyanate (MDI) is thought to be an important step in the development of diisocyanate (dNCO)-specific allergic sensitization; however, MDI-haptenated albumins used to screen specific antibody are often poorly characterized. Recently, the need to develop standardized immunoassays using a consistent, well-characterized dNCO-haptenated protein to screen for the presence of MDI-specific IgE and IgG from workers' sera has been emphasized and recognized. This has been challenging to achieve due to the bivalent electrophilic nature of dNCOs, leading to the capability to produce multiple cross-linked protein species and polymeric additions to proteins.

View Article and Find Full Text PDF