98%
921
2 minutes
20
Denoising and contrast enhancement play key roles in optimizing the trade-off between image quality and X-ray dose. However, these tasks present multiple challenges raised by noise level, low visibility of fine anatomical structures, heterogeneous conditions due to different exposure parameters, and patient characteristics. This work proposes a new method to address these challenges. We first introduce a patch-based filter adapted to the properties of the noise corrupting X-ray images. The filtered images are then used as oracles to define non parametric noise containment maps that, when applied in a multiscale contrast enhancement framework, allow optimizing the trade-off between improvement of the visibility of anatomical structures and noise reduction. A significant amount of tests on both phantoms and clinical images has shown that the proposed method is better suited than others for visual inspection for diagnosis, even when compared to an algorithm used to process low dose images in clinical routine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.media.2015.11.002 | DOI Listing |
J Phys Chem A
September 2025
Department of Chemistry, Tsinghua University, Beijing 100084, China.
A series of Cu-based single-atom catalysts (SACs) with asymmetric coordination were designed to accelerate lithium-sulfur (Li-S) chemistry. The electronegativity contrast from the dopant induces a localized electronic asymmetry that amplifies Jahn-Teller distortion at the Cu center. This distortion profoundly modulates the Cu 3d electronic structure and its interaction with Li-S intermediates.
View Article and Find Full Text PDFJAMA
September 2025
Division of Surgery and Interventional Science, UCL, London, United Kingdom.
Importance: Multiparametric magnetic resonance imaging (MRI), with or without prostate biopsy, has become the standard of care for diagnosing clinically significant prostate cancer. Resource capacity limits widespread adoption. Biparametric MRI, which omits the gadolinium contrast sequence, is a shorter and cheaper alternative offering time-saving capacity gains for health systems globally.
View Article and Find Full Text PDFTransl Stroke Res
September 2025
Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.
Recent studies have shown that the glymphatic system plays a crucial role in driving hyperacute edema after ischemic stroke. This has sparked interest in understanding how this system changes in later phases of ischemic stroke. In this study, we utilized cisternal contrast-enhanced magnetic resonance imaging (CE-MRI) and immunofluorescence staining to investigate glymphatic system alterations at subacute and chronic phases of ischemic stroke.
View Article and Find Full Text PDFAbdom Radiol (NY)
September 2025
Peking University First Hospital, Beijing, China.
Purpose: To evaluate the feasibility and clinical utility of non-contrast magnetic resonance angiography (NC-MRA) using a modified balanced steady-state free precession (b-SSFP) technique combined with arterial spin labeling (ASL) for post-embolotherapy follow-up of renal artery aneurysms (RAAs), with digital subtraction angiography (DSA) as the reference standard.
Method: A total of 57 patients with RAAs underwent embolotherapy between June 2013 and July 2024. Among them, 15 RAAs from 14 patients underwent post-embolization surveillance with the NC-MRA and DSA.
J Magn Reson Imaging
September 2025
Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Background: Carotid artery stenosis is a major cause of stroke. Non-contrast MR angiography (MRA) using time-spatial labeling inversion pulse (Time-SLIP) may offer potential advantages over 3D time-of-flight (TOF)-MRA for simultaneous visualization of carotid, vertebral, and subclavian arteries, but remains uninvestigated.
Purpose: To determine optimal black blood inversion time (TI) for visualizing the carotid and subclavian arteries using three-dimensional (3D) fast field echo (FFE) Time-SLIP MRA, and to compare its image quality with 3D TOF-MRA.