The aim of this study was to compare conventional photoplethysmography (PPG) in a finger with PPG using an integrating sphere (ISPPG) to enhance scattered light collection. Two representative wavelengths were used; 1160 nm, a window through the absorption spectra of water and alcohol, and 1600 nm around where water absorption is high and there is an absorption peak of blood glucose. Simultaneous transmission-type measurements were made with conventional PPG and with ISPPG for each wavelength in the tips of index fingers of both hands in a total of 10 healthy young male and female volunteers (21.7 ± 1.6 years old). During a 5 min period in which subjects were in a relaxed state we determined the signal-to-noise ratio, SNR, and the PPG detectability (or sensitivity) by the two techniques. SNR during the test period was significantly higher with ISPPG as compared with conventional PPG, especially for the 1600 nm wavelength. PPG signals with 1600 nm could scarcely be detected by conventional PPG, while they could be detected with good sensitively by ISPPG. We conclude that under controlled conditions ISPPG has better SNR and higher sensitivity than conventional transmission PPG, especially in wavelength regions where water absorption is high but where there is potential for practical measurement of blood constituents including glucose.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4670230 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0143506 | PLOS |
ACS Omega
August 2025
Department of Petroleum Engineering, IIT (ISM), Dhanbad, Jharkhand 826004, India.
Preformed particle gels (PPGs) have been introduced as an efficacious chemical technology to alleviate or reduce unwanted water production from heterogeneous mature oil fields. However, there are some limitations to the existing developed PPGs, such as mechanical robustness, temperature stability, and formation fluid resistance. To address these limitations, a nanomaterial-reinforced preformed particle gel was introduced.
View Article and Find Full Text PDFSensors (Basel)
July 2025
Educational Physiology Laboratory, Graduate School of Education, The University of Tokyo, Tokyo 113-0033, Japan.
In recent years, the use of photoplethysmography (PPG)-based heart rate detection has gained considerable attention as a cost-effective alternative to conventional electrocardiography (ECG) for applications in healthcare and fitness tracking. Although deep learning methods have shown promise in heart rate estimation and motion artifact removal from PPG signals recorded during physical activity, their computational requirements and need for extensive training data make them less practical for real-world conditions when ground truth data is unavailable for calibration. This study presents a one-size-fits-all approach for heart rate estimation during physical activity that employs aggregation-based techniques to track heart rate and minimize the effects of motion artifacts, without relying on complex machine learning or deep learning techniques.
View Article and Find Full Text PDFMetabol Open
September 2025
Department of Internal Medicine, Minami Osaka Hospital, 1-18-18 Higashikagaya, Suminoe-ku, Osaka, 559-0012, Japan.
For optimal postprandial glucose (PPG) management, rapid-acting insulin analogs (RAA) should be administered 15 min before a meal; however, this may not be possible for some individuals. Ultra-rapid lispro (URLi) can be administered 0-2 min before or <20 min after a meal, which may improve patient satisfaction and PPG management. In this pilot study, we evaluated changes in quality of life (QOL) and glycemic management among Japanese outpatients with type 2 diabetes mellitus (T2DM) who switched from RAA to URLi.
View Article and Find Full Text PDFDigit Health
July 2025
Pediatric and Adolescent Unit, Department of Internal Medicine, University of Pavia, Pavia, Italy.
Background: Photoplethysmography (PPG) is an effective non-contact technique for measuring vital signs. This report aims to evaluate whether a non-contact PPG-based mobile application supports an appropriate level of accuracy in monitoring SpO, HR, and BP, compared against clinically approved medical devices.
Methods: Adult volunteers (≥18 years, both male and female) were consecutively enrolled from September to November 2024.
Antibiotics (Basel)
June 2025
Program in Biodiversity and Biotechnology of the Bionorte Network (PPG-BIONORTE), Amazonas State University (UEA), Manaus 69065-001, AM, Brazil.
Cryptococcosis, caused by and species complexes, remains a significant health concern, particularly among immunocompromised patients. The emergence of antifungal resistance and toxicity of conventional treatment underscore the urgent need for novel therapeutic approaches. Combination therapies represent a promising strategy to enhance efficacy and overcome resistance.
View Article and Find Full Text PDF