Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Introduction: A variety of methods are used to assess parasympathetic activity in athletes targeting different organs; however, the reliability of or interchangeability between measurement procedures is not clear.
Objective: The purpose of this study is to identify the repeatability of two parasympathetic activity measurement procedures, the HR variability during a 4-s exercise test (4sET), and the contractile properties of the pupil (pupillometry), and to assess their agreement. The secondary objective of this study is to assess their relationship with the bronchodilating effect of inhaled ipratropium bromide (iIB), blocking parasympathetic signals to the lungs.
Methods: Forty athletic subjects were enrolled in a cross-sectional study. After 15-min resting in semidarkness, subjects underwent pupillometry (PLR-200™, NeurOptics Inc., CA), followed by 4sET on a cycle ergometer. HR variability was assessed by Polar Electro® HR monitor (RS-800CX/G3; Oy, Kempele, Finland). Both protocols were repeated after 5 min. Statistical analysis was performed according to Bland and Altman and by using Pearson's correlation coefficient and intraclass correlation. Lung function measurements by flow volume curves were performed before and 45 min after iIB.
Results: The means of differences were 1.21% (limits of agreement, -3.59 to 6.02) for pupil constriction and 0.05 mm (-0.28 to 0.39) for pupil amplitude. The mean of differences for 4sET was 0.005 (-0.31 to 0.32). A very weak intraclass correlation (r = -0.01, P = 0.58) showed no agreement between the methods. No correlation was observed between pupillometry variables or 4sET with the change in lung function after iIB.
Conclusion: Pupillometry showed better repeatability compared with the 4sET. There is poor agreement between parasympathetic activity levels measured in three different target organs of athletic subjects; the heart, the pupil, and the lung. Thus, methods assessing parasympathetic activity in different target organs cannot be used interchangeably.