A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Screw Loosening and Pelvic Canal Narrowing After Lateral Plating of Feline Ilial Fractures With Locking and Nonlocking Plates. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To compare the frequency of complications, including screw loosening and pelvic canal narrowing, associated with dynamic compression plating, locking plating, and double locking plating of ilial fractures in cats.

Study Design: Historical cohort study.

Methods: The radiographs and medical records of cats with pelvic fractures that were presented between 2004 and 2013 were reviewed. The cases were categorized based on the plate type and number as dynamic compression plate (DCP), single locking plate (LPS) and double locking plates (dLPS). The frequency of screw loosening was compared across categories using a Fisher's exact test. The change in pelvic alignment, described by the change in sacral index (postoperative sacral index-followup sacral index), was compared across plate categories using ANOVA.

Results: The frequency of screw loosening for DCP (5/10) was significantly higher than LPS (1/13) and dLPS (0/11) (P = .05, P = .012, respectively). There was no significant difference in the SI change across plate categories. The mean change in sacral index for DCP was -0.11 (95%CI -0.25 to 0.03), for LPS was 0.0007 (95%CI -0.07 to 0.08), and for dLPS was -0.01 (95%CI -0.04 to 0.02). None of the cats showed constipation postoperatively.

Conclusion: Screw loosening occurred less often but the change in pelvic canal alignment was not significantly different in ilial fractures repaired with LPS or dLPS compared to ilial fractures repaired with DCP. Locking plating of ilial fractures in cats may offer advantages compared to nonlocking plating.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vsu.12367DOI Listing

Publication Analysis

Top Keywords

screw loosening
20
ilial fractures
20
pelvic canal
12
locking plating
12
loosening pelvic
8
canal narrowing
8
dynamic compression
8
double locking
8
plating ilial
8
frequency screw
8

Similar Publications