98%
921
2 minutes
20
Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization.
Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors' specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth.
Results: The authors' results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm.
Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.4921066 | DOI Listing |
Background: Acupuncture is a widely recognized complementary therapy with proven therapeutic benefits; however, concerns regarding patient safety persist due to adverse events ranging from minor complications to severe outcomes like pneumothorax and nerve injury.
Objective: This study aims to identify common adverse events in acupuncture, propose innovative risk mitigation strategies, establish standardized best practices, enhance practitioner training, and examine global disparities in safety protocols.
Design: Comprehensive review of existing literature, clinical case studies, and international safety guidelines.
NAR Genom Bioinform
September 2025
School of Computational and Integrative Sciences, Jawaharlal Nehru University, New Delhi, India.
The translatability of patient-derived xenograft (PDX)-generated clinical data into patient-specific outcomes for therapeutic guidance is limited by the challenges in generalizability of models across patients, treatments, and cancer types. Previously, machine learning (ML) models have been developed for the two most abundant cancer types, i.e.
View Article and Find Full Text PDFAnn Plast Surg
September 2025
From the Department of Plastic Surgery, Section of Surgical Sciences, Vanderbilt University Medical Center, Nashville, TN.
Hypertrophic scarring (HTS) remains a critical challenge in burn care, often resulting in debilitating contractures, chronic pain, and significant psychosocial burden. While current treatment emphasizes structural repair, recent advances underscore the importance of addressing the biological drivers of fibrosis. This review synthesizes evolving strategies in burn scar prevention, highlighting tissue-engineered matrices, autologous cell therapies, and predictive molecular tools that shift care from reactive to regenerative.
View Article and Find Full Text PDFAdv Healthc Mater
September 2025
Smart Materials, NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, Sønderborg, DK-6400, Denmark.
This study presents a comprehensive framework combining Selective Laser Melting (SLM) of Titanium (Ti64) alloys, finite element simulation, and artificial intelligence (AI) to advance orthopedic implants' design and predictive evaluation. Dense Ti64 specimens are fabricated using ten distinct SLM parameter sets to explore the effects of volumetric energy density (VED) on mechanical behavior, porosity distribution, and microstructural integrity. Optimal VED ranges are identified to balance defect minimization and mechanical performance, with porosity levels strongly influencing tensile strength and Young's modulus.
View Article and Find Full Text PDFGut Liver
September 2025
Department of Internal Medicine, Chonnam National University Medical School, Gwangju, Korea.
Management of common bile duct (CBD) stones has evolved substantially with the advent of endoscopic techniques and dedicated high-end devices. Endoscopic retrograde cholangiopancreatography (ERCP) has become a widespread essential technique for managing CBD stones, with high success rates in standard cases. However, for patients with large stones, stones in an impacted state, and stones in anatomically challenging regions, advanced strategies using various dedicated devices may be needed.
View Article and Find Full Text PDF