Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A novel evanescent wave biosensor based on modal interaction between the fundamental mode and the second order mode is proposed and numerically demonstrated. By taking advantage of their symmetries, it is possible to design a device where only the fundamental and the second order modes can propagate, without excitation of the first order mode. With this selection of modes it is possible to achieve a high sensitivity behavior in the biosensor configuration, due to the strong interaction between the evanescent field and the outer surface as compared to previous evanescent wave-based biosensor designs.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.23.011985DOI Listing

Publication Analysis

Top Keywords

second order
8
order mode
8
study low-cost
4
low-cost trimodal
4
trimodal polymer
4
polymer waveguide
4
waveguide interferometric
4
interferometric optical
4
optical biosensors
4
biosensors novel
4

Similar Publications

This study quantitatively evaluated the adsorption performance of natural bentonite for removing three dye classes-cationic (Basic dye: BEZACRYL RED GRL), anionic (Reactive dye: AVITERA LIGHT RED SE), and non-ionic (Disperse dye: BEMACRON BLUE HP3R) from synthetic textile wastewater. Batch adsorption experiments were conducted under varying conditions of contact time (15-90 min), adsorbent dosage (20-60 g L⁻), pH (4 and 12), and temperature (25-100 °C), with dye concentrations quantified by UV-Vis spectroscopy. At a contact time of 30 min and room temperature (25 °C), maximum removal efficiencies reached 99.

View Article and Find Full Text PDF

Cadmium (Cd) contamination in water poses a critical global challenge. A novel nanocomposite, montmorillonite (Mt)-supported nanoscale zero-valent iron (Mt-nZVI), synthesized by liquid phase reduction, offers a promising method for effectively removing Cd. The material underwent characterization through various techniques, including X-ray diffraction (XRD) and Scanning Electron Microscope(SEM).

View Article and Find Full Text PDF

Fractional-order adaptive fuzzy decentralized tracking control for steer-by-wire system.

ISA Trans

August 2025

Department of Vehicle Engineering and Jiangsu Engineering Research Center of Vehicle Distributed Drive and Intelligent Wire Control Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China; Department of Vehicle Engineering and Jiangsu Engineering Research Center of Vehi

The steer-by-wire (SbW) system, as the core component of vehicle steering, needs to track the front wheel angle accurately. To mitigate the angle tracking accuracy degradation caused by D-Q axes coupling, time-varying motor electrical parameters, and load disturbance, a fractional-order adaptive fuzzy decentralized tracking control (FAFDTC) strategy is proposed in this paper. First, considering time-varying motor parameters, D-Q axes coupling, and fractional-order characteristics of components, a fractional-order SbW interconnected system is constructed to enhance its ability to characterize nonlinearities, time-varying dynamics, and system coupling.

View Article and Find Full Text PDF

[Research status and future direction of irreversible EGFR-TKI in non-small cell lung cancer].

Zhonghua Jie He He Hu Xi Za Zhi

September 2025

Department of nursing, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510000, China.

Epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKI) are important treatments for EGFR mutant non-small cell lung cancer (NSCLC). However, the first and second generation EGFR-TKI face clinical limitations due to acquired resistance, such as the T790M mutation. Irreversible EGFR-TKI can significantly prolong the survival of patients by enhancing the inhibition of drug-resistant mutations through the covalent binding mechanism.

View Article and Find Full Text PDF

Severe pneumonia, as a critical and prevalent condition of the respiratory system, poses a significant threat to patient survival and health outcomes. This article focuses on the similarities and differences between community-acquired pneumonia (CAP) and hospital-acquired pneumonia (HAP)/ventilator-associated pneumonia (VAP). There is significant divergence in the predominant pathogens between severe community-acquired pneumonia (SCAP) and HAP/VAP.

View Article and Find Full Text PDF