A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Ion pair-dispersive liquid-liquid microextraction coupled to microsample injection system-flame atomic absorption spectrometry for determination of gold at trace level in real samples. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A novel ion pair-dispersive liquid-liquid microextraction (IP-DLLME) of gold followed by its determination with microsample injection system-flame atomic absorption spectrometry (MIS-FAAS) detection was developed. The extraction method was based on the reaction of anionic tetrachloro gold(III) complex with the cationic form of Rhodamine B to give a violet ion pair complex, which is extracted from 1.0 mol L(-1) HCl solution of 8.0 mL to fine droplets of chloroform of 500 µL. A Plackett-Burman experimental design of MINITAB statistical program was employed to optimize the influence of main parameters to be controlled in DLLME. After optimizing the extraction conditions, gold was quantitatively recovered by preconcentration factor of 40, limit of detection (LOD) of 1.8 μg L(-1) and relative standard deviation of less than 6.8%. The proposed method was successfully applied to the preconcentration and determination of gold in some samples such as tap water, waste water, copper electrolysis solution and copper wire coated nickel.

Download full-text PDF

Source
http://dx.doi.org/10.17344/acsi.2014.897DOI Listing

Publication Analysis

Top Keywords

ion pair-dispersive
8
pair-dispersive liquid-liquid
8
liquid-liquid microextraction
8
microsample injection
8
injection system-flame
8
system-flame atomic
8
atomic absorption
8
absorption spectrometry
8
determination gold
8
microextraction coupled
4

Similar Publications