A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

"Why Not Stoichiometry" versus "Stoichiometry—Why Not?" Part III: Extension of GATES/GEB on Complex Dynamic Redox Systems. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In the third part of a series of articles issued under a common title, some examples of complex dynamic redox systems are presented and considered from analytical and physico-chemical viewpoints; the analysis is a leitmotiv for detailed, physico-chemical considerations. All attainable physico-chemical knowledge is involved in algorithms applied for resolution of the systems, realized with use of iterative computer programs. The first redox system (System I) is related to titration of FeSO4 + H2C2O4 with KMnO4 solution in acidic (H2SO4) medium, where simultaneous determination of both analytes from a single curve of potentiometric titration is possible. The possibility of the formation of precipitates (FeC2O4 and/or MnC2O4) in this system is taken into considerations. The second system (System II) relates to the complete analytical procedure involved in the iodometric determination of Cu; four consecutive steps of this analysis are considered. As a reasonable tool for explanation of processes occurring during simulated redox titration, speciation diagrams are suggested. This explanation is based on graphical presentation of results obtained from the calculations. The calculations made for this purpose are performed in accordance with principles of the generalized approach to electrolytic systems (GATES) with generalized electron balance (GEB) or GATES/GEB and realized with use of iterative computer programs offered by MATLAB. The reactions proceeding in this system can be formulated, together with their efficiencies, at any stage of the titration. Stoichiometry is considered as the derivative concept when put in context with GATES/GEB. The article illustrates the enormous possibilities and advantages offered by GATES/GEB.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10408347.2014.953673DOI Listing

Publication Analysis

Top Keywords

complex dynamic
8
dynamic redox
8
redox systems
8
realized iterative
8
iterative computer
8
computer programs
8
system system
8
system
6
"why stoichiometry"
4
stoichiometry" versus
4

Similar Publications