Tracking systems for virtual rehabilitation: objective performance vs. subjective experience. A practical scenario.

Sensors (Basel)

Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.

Published: March 2015


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Motion tracking systems are commonly used in virtual reality-based interventions to detect movements in the real world and transfer them to the virtual environment. There are different tracking solutions based on different physical principles, which mainly define their performance parameters. However, special requirements have to be considered for rehabilitation purposes. This paper studies and compares the accuracy and jitter of three tracking solutions (optical, electromagnetic, and skeleton tracking) in a practical scenario and analyzes the subjective perceptions of 19 healthy subjects, 22 stroke survivors, and 14 physical therapists. The optical tracking system provided the best accuracy (1.074 ± 0.417 cm) while the electromagnetic device provided the most inaccurate results (11.027 ± 2.364 cm). However, this tracking solution provided the best jitter values (0.324 ± 0.093 cm), in contrast to the skeleton tracking, which had the worst results (1.522 ± 0.858 cm). Healthy individuals and professionals preferred the skeleton tracking solution rather than the optical and electromagnetic solution (in that order). Individuals with stroke chose the optical solution over the other options. Our results show that subjective perceptions and preferences are far from being constant among different populations, thus suggesting that these considerations, together with the performance parameters, should be also taken into account when designing a rehabilitation system.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435107PMC
http://dx.doi.org/10.3390/s150306586DOI Listing

Publication Analysis

Top Keywords

skeleton tracking
12
tracking
9
tracking systems
8
practical scenario
8
tracking solutions
8
performance parameters
8
optical electromagnetic
8
subjective perceptions
8
provided best
8
tracking solution
8

Similar Publications

Glenohumeral instability is a common injury affecting contact and collision athletes. Male sex, younger age at time of first dislocation, and contact sports participation are risk factors for recurrent instability. MRI is the gold standard to evaluate soft tissue structures, while CT is beneficial in quantifying glenoid bone loss and identifying on-track and off-track Hill-Sachs lesions.

View Article and Find Full Text PDF

This study aims to clarify the dynamic changes in the cervical lordotic angle (CLA) during normal swallowing using an automated motion analysis method. Physiological cervical lordosis is crucial for spinal alignment and musculoskeletal function. While previous studies have noted the relevance of cervical curvature in clinical contexts, its dynamic modulation during swallowing has not been well studied.

View Article and Find Full Text PDF

Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.

View Article and Find Full Text PDF

Association of Energy, Macronutrients, and Fiber Intakes with Bone Health in Adolescent Athletes.

Calcif Tissue Int

September 2025

Department of Physical Education, Center for Health and Sports Sciences, Santa Catarina State University, Rua Pascoal Simone, 358, Coqueiros, Florianópolis, State of Santa Catarina, CEP: 88080-350, Brazil.

This study investigated the association between energy and macronutrient intake and bone health in 63 adolescents of both sexes who participated in volleyball, track and field, or swimming. Bone mineral content (BMC) and density (BMD) of the total body less head (TBLH), lumbar spine (L1-L4), and femoral neck were assessed using DXA. Bone geometry parameters, including cross-sectional area (CSA), cross-sectional moment of inertia (CSMI), and section modulus, were estimated.

View Article and Find Full Text PDF

[Functional Outcomes of Treatment of the Mallet Finger with a Bone Fragment Using the Ishiguro Extension].

Acta Chir Orthop Traumatol Cech

June 2025

Klinika detske a dospele ortopedie a traumatologie 2. lekarske fakulty Univerzity Karlovy a Fakultni nemocnice v Motole, Praha.

Purpose Of The Study: The study aims to evaluate the mid-term functional and subjective outcomes of treatment of the mallet finger with a bone fragment using the Ishiguro extension block pinning. The hypothesis was that this technique provides reliable and high-quality outcomes with a low complication rate.

Material And Methods: The study included 54 patients aged 7-17 years who underwent surgery at our department between 2017 and 2022.

View Article and Find Full Text PDF