A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Randomized cinefluoroscopic comparison of cervical spine motion using McGrath series 5 and Macintosh laryngoscope for intubation with manual in-line stabilization. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Intubation in patients with suspected cervical spine injury must be cautiously performed to avoid any further neurologic trauma. Several intubation techniques have been introduced to minimize cervical spine motion such as the use of the videolaryngoscope.

Objective: The present study aims to compare the movement of the cervical spine during intubation by using McGrath series 5 videolaryngoscope (MGL) and that of the conventional Macintosh laryngoscope from cinefluoroscopic imaging.

Material And Method: Twenty-two patients undergoing elective orthopedic surgery that did not involve cervical spine procedure and required general anesthesia were recruited into the study. All patients were randomized either to have intubation with MGL (n = 11) or Macintosh laryngoscope (n = 11) in a neutral position with manual in-line stabilization (MILS). The primary outcome was the cervical vertebral angle changes pre- and post-intubation, measured by cinefluoroscopy. The number of intubation attempts, the laryngoscopic view, the time to intubation, and the incidence ofany complications were recorded as well.

Results: Eleven patients were included in each group without any exclusion from the study. The cervical vertebral angle changes pre- and post-intubation with the MGL was less than with the Macintosh laryngoscope at C3/4 (2.00 vs. 4.27 degrees, respectively; p-value = 0.034) and the cumulative changes of all cervical spine levels (9.18 vs. 17.18 degrees, respectively; p-value = 0.017). However, the time to intubation with the MGL was longer (35.07 vs. 23.21 seconds, p-value = 0.004), the laryngoscope view was better. There were no statistically significant differences in the intubation success rate, the number of attempts, and the incidence of complications.

Conclusion: Orotracheal intubation with MGL provided less cervical spine motion and improved visualization of the vocal cords, without causing adverse consequences as compared with Macintosh laryngoscope and MILS.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cervical spine
28
macintosh laryngoscope
20
spine motion
12
intubation mgl
12
intubation
10
cervical
9
mcgrath series
8
manual in-line
8
in-line stabilization
8
mgl macintosh
8