A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Prediction of the biomechanical effects of compression therapy by finite element modeling and ultrasound elastography. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Goal: In the present study, the biomechanical response of soft tissues from the fascia cruris to the skin is studied in the human leg under elastic compression.

Methods: The distribution of elastic moduli in these tissues is measured for a volunteer at inactive and active muscle states using transient ultrasound elastography (TUSE). After registering the elasticity maps against magnetic resonance imaging scans of the same volunteer, patient-specific finite element (FE) models are developed for the leg cross section at inactive and active muscle states. Elastic properties obtained with TUSE are assigned at each Gauss point of the models. The response to 20 mmHg elastic compression is eventually predicted with the models.

Results: Results show significantly higher elastic moduli in the fascia cruris tissue and also a significant increase of elastic moduli at active muscle state.

Conclusion: This seems to have a marginal impact on pressure maps in the soft tissues of the leg predicted by the FE models. There is still an effect on the reduction of vein diameter induced by elastic compression, which is decreased at active muscle state.

Significance: The discussion of this paper highlights the benefits of using elastography to reconstruct patient-specific FE models of soft tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2014.2378553DOI Listing

Publication Analysis

Top Keywords

active muscle
16
soft tissues
12
elastic moduli
12
finite element
8
ultrasound elastography
8
fascia cruris
8
inactive active
8
muscle states
8
elastic compression
8
elastic
7

Similar Publications