Diffusive gradients in thin-films (DGT) sampler with a polyquaternary ammonium salt (PQAS) aqueous solution as a binding phase and a dialysis membrane as a diffusive phase (PQAS DGT) was developed for the measurement of dissolved reactive phosphorus (DRP) in water. The performance of PQAS DGT was not dependent upon pH 3-10 and ionic strength from 1 × 10(-4) to 1 mol L(-1). The effective binding capacity of PQAS DGT containing 2.0 mL of 0.050 mol L(-1) PQAS solution was estimated as 9.9 μg cm(-2). The measurement of DRP in a synthetic solution by PQAS DGT over a 48 h deployment period demonstrated high consistency with the concentration of DRP in the synthetic solution measured directly by the ammonium molybdate spectrophotometric method. Field deployments of PQAS DGT samplers allowed for accurate measurement of the DRP concentration in situ. The advantages of PQAS DGT include no requirement of the elution steps and direct concentration measurements of the binding phase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jf5040702 | DOI Listing |
J Agric Food Chem
December 2014
College of Chemistry, Chemical Engineering and Food Safety, Research Institute of Food Science, and Food Safety Key Laboratory of Liaoning Province, Bohai University, Jinzhou, Liaoning 121013, People's Republic of China.
Diffusive gradients in thin-films (DGT) sampler with a polyquaternary ammonium salt (PQAS) aqueous solution as a binding phase and a dialysis membrane as a diffusive phase (PQAS DGT) was developed for the measurement of dissolved reactive phosphorus (DRP) in water. The performance of PQAS DGT was not dependent upon pH 3-10 and ionic strength from 1 × 10(-4) to 1 mol L(-1). The effective binding capacity of PQAS DGT containing 2.
View Article and Find Full Text PDFJ Hazard Mater
April 2014
College of Chemistry, Chemical Engineering and Food Safety, Bohai University, China; Research Institute of Food Science, Bohai University, China; Food Safety Key Lab of Liaoning Province, Jinzhou 121013, China. Electronic address:
A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3-12 and ionic strength from 1 × 10(-3) to 1 molL(-1). DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively.