A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of changes in sintering parameters on monolithic translucent zirconia. | LitMetric

Effect of changes in sintering parameters on monolithic translucent zirconia.

Dent Mater

Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.

Published: December 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Aim of this study was to evaluate the effect of different sintering parameters on color reproduction, translucency and biaxial flexural strength of monolithic zirconia.

Methods: Translucent zirconia discs having 15mm diameter, 1mm thickness, and shade A3 were milled and divided according to the sintering temperatures (1460°C, 1530°C, and 1600°C) into three groups (n=30). Each group was later divided into three subgroups (n=10) according to the sintering holding time (1, 2, and 4h). Easyshade spectrophotometer (Vita, Bad Säckingen, Germany) was used to obtain the ΔE between the specimens and the shade A3. Mean ΔE values below 3.0 were considered "clinically imperceptible", ΔE values between 3.0 and 5.0 were considered "clinically acceptable" and ΔE values above 5.0 were considered "clinically unacceptable". Contrast ratio (CR) was obtained after comparing the reflectance of light through the specimens over black and white background. Biaxial flexural strength was tested using the piston-on-three balls technique in a universal testing machine.

Results: Mean ΔE results ranged from 4.4 to 2.2. Statistically significant decrease in the Delta E was observed as the sintering time and temperature increased. CR decreased from 0.75 to 0.68 as the sintering time and temperature increased. No significant change in the biaxial flexural strength was observed.

Significance: Sintering zirconia using long cycles and high temperatures will result in reduction of ΔE and CR. Biaxial flexural strength is not affected by changes in the evaluated sintering parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2014.09.003DOI Listing

Publication Analysis

Top Keywords

biaxial flexural
16
flexural strength
16
sintering parameters
12
Δe values
12
values considered
12
considered "clinically
12
translucent zirconia
8
sintering time
8
time temperature
8
temperature increased
8

Similar Publications