A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of 3- and 4-mm interimplant distances on the height of interimplant bone crest: a histomorphometric evaluation measured on bone level dental implants in minipig. | LitMetric

Effect of 3- and 4-mm interimplant distances on the height of interimplant bone crest: a histomorphometric evaluation measured on bone level dental implants in minipig.

Implant Dent

*President and CEO, VIZSTARA, Englewood Cliffs, NJ. †Clinical Associate Professor, Educational Coordinator II, Department of Periodontology and Implant Dentistry, New York University, College of Dentistry, New York, NY. ‡Clinical Associate Professor, Department of Cardiology and Comprehensive Ca

Published: October 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To analyze crestal bone loss changes that may affect the gingival height around an implant and bone loss in interproximal areas. When implants are placed adjacent to one another, interimplant bone loss around 1 implant may combine with the implant bone loss around the adjacent implant to affect the crestal bone loss interproximally.

Materials And Methods: The primary objective of this study was to evaluate histologically and histomorphometrically the effect that this implant design with a horizontally displaced implant-abutment junction has on the height of the crest of bone, between adjacent implants separated by 2 different distances: 4 mm and 3 mm. A secondary objective was to evaluate the percentage of bone-to-implant contact, interproximal soft tissue height, location of the junctional epithelium, and length of connective tissue contact to abutment and/or implant, for the 2 different distances.

Results: Results showed that the interproximal bone loss measured from the edge of the implant platform to the bone crest was not different for interimplant distances of 4 or 3 mm. In addition, the secondary objective parameters also demonstrated similar results between the 2 interimplant distances.

Conclusion: This study showed that interimplant bone levels can usually be maintained at similar levels for 4- and 3-mm distances during at least 2 months.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ID.0000000000000153DOI Listing

Publication Analysis

Top Keywords

bone loss
24
interimplant bone
12
bone
11
interimplant distances
8
bone crest
8
crestal bone
8
implant bone
8
secondary objective
8
implant
7
loss
6

Similar Publications