A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Cyanide detection using a benzimidazole derivative in aqueous media. | LitMetric

Cyanide detection using a benzimidazole derivative in aqueous media.

Spectrochim Acta A Mol Biomol Spectrosc

College of Chemical and Biological Engineering, Lanzhou Jiaotong University, Lanzhou, Gansu 730070, PR China.

Published: December 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A novel cyanide selective fluorescent chemosensor S1 based on benzimidazole group and naphthalene group as the fluorescence signal group had been designed and synthesized. The receptor could instantly detect CN(-) anion over other anions such as F(-), Cl(-), Br(-), I(-), AcO(-), H2PO4(-), HSO4(-), SCN(-) and ClO4(-) by fluorescence spectroscopy changes in aqueous solution (H2O/DMSO, 8:2, v/v) with specific selectivity and high sensitivity. The fluorescence color of the solution containing sensor S1 induced a remarkable color change from pale blue to mazarine only after the addition of CN(-) in aqueous solution while other anions did not cause obvious color change. Moreover, further study demonstrates the detection limit on fluorescence response of the sensor to CN(-) is down to 8.8×10(-8)M, which is far lower than the WHO guideline of 1.9×10(-6)M. Test strips based on S1 were fabricated, which could act as a convenient and efficient CN(-) test kit to detect CN(-) in pure water for "in-the-field" measurement. Thus, the probe should be potential applications in an aqueous environment for the monitoring of cyanide.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2014.06.060DOI Listing

Publication Analysis

Top Keywords

detect cn-
8
aqueous solution
8
color change
8
cn-
5
cyanide detection
4
detection benzimidazole
4
benzimidazole derivative
4
aqueous
4
derivative aqueous
4
aqueous media
4

Similar Publications