Black-blood multicontrast imaging of carotid arteries with DANTE-prepared 2D and 3D MR imaging.

Radiology

From the Functional Magnetic Resonance Imaging of the Brain Centre, Nuffield Department of Clinical Neurosciences (L.L., J.N., P.J.), Acute Vascular Imaging Centre, Radcliffe Department of Medicine (J.T.C., R.P.C.), University of Oxford Centre for Clinical Magnetic Resonance Research, Radcliffe Depa

Published: November 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To prospectively compare the black-blood ( BB black blood ) imaging efficiency of a delay alternating with nutation for tailored excitation ( DANTE delay alternating with nutation for tailored excitation ) preparation module with conventional double inversion-recovery ( DIR double inversion recovery ) and motion-sensitive driven equilibrium ( MSDE motion-sensitive driven equilibrium ) preparation modules and to introduce a new three-dimensional ( 3D three-dimensional ) T1-weighted magnetic resonance (MR) imaging sequence.

Materials And Methods: Carotid artery wall imaging was performed in 10 healthy volunteers and 15 patients in accordance with an institutional review board-approved protocol. Two-dimensional ( 2D two-dimensional ) turbo spin-echo ( TSE turbo spin echo ) and 3D three-dimensional fast low-angle shot ( FLASH fast low-angle shot ) sequences served as readout modules. DANTE delay alternating with nutation for tailored excitation -prepared T1-, T2-, and proton density-weighted 2D two-dimensional TSE turbo spin echo images, as well as T1-weighted 3D three-dimensional DANTE delay alternating with nutation for tailored excitation -prepared FLASH fast low-angle shot (hereafter, 3D three-dimensional DASH DANTE-prepared FLASH ) images, were acquired in the region of the carotid artery bifurcation. For comparison, 2D two-dimensional DIR double inversion recovery -prepared, 2D two-dimensional MSDE motion-sensitive driven equilibrium -prepared multicontrast TSE turbo spin echo , and 3D three-dimensional MSDE motion-sensitive driven equilibrium -prepared FLASH fast low-angle shot (hereafter, 3D three-dimensional MERGE MSDE-prepared FLASH ) MR images were also acquired. The effective contrast-to-noise ratio ( CNReff effective contrast-to-noise ratio ) per unit time was calculated for all sequences. Paired t tests were performed to test within-group differences in vessel wall CNReff effective contrast-to-noise ratio .

Results: The CNReff effective contrast-to-noise ratio of DANTE delay alternating with nutation for tailored excitation -prepared T1-, T2-, and proton density-weighted sequences was 27.3, 14.7, and 25.7 mm(-1)min(-1/2), respectively; this represented an improvement of approximately 25%-100% (P < .05) when compared with the CNReff effective contrast-to-noise ratio attained with existing methods. The 3D three-dimensional DASH DANTE-prepared FLASH technique proved to be a fast (<2 seconds per section) and high-spatial-resolution (0.6 mm isotropic) BB black blood technique with higher (75%-100% improvement, P < .001) signal-to-noise ratio efficiency than the 3D three-dimensional MERGE MSDE-prepared FLASH technique.

Conclusion: The DANTE delay alternating with nutation for tailored excitation -prepared multicontrast 2D two-dimensional BB black blood technique is a promising new tool for MR imaging of carotid artery walls. Additionally, the 3D three-dimensional DASH DANTE-prepared FLASH sequence enables 3D three-dimensional high-spatial-resolution fast T1-weighted imaging of carotid artery walls. ©RSNA, 2014 Online supplemental material is available for this article .

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.14131717DOI Listing

Publication Analysis

Top Keywords

delay alternating
20
alternating nutation
20
nutation tailored
20
tailored excitation
20
effective contrast-to-noise
20
contrast-to-noise ratio
20
dante delay
16
motion-sensitive driven
16
driven equilibrium
16
fast low-angle
16

Similar Publications

Clinical progression on CDR-SB©: Progression-free time at each 0.5 unit level in dominantly inherited and sporadic Alzheimer's disease populations.

Alzheimers Dement

September 2025

Department of Psychiatry and The Behavioral Sciences, Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.

Introduction: Clinical Dementia Rating Sum of Boxes (CDR-SB) is a reliable and clinically meaningful composite for assessing treatment effects in Alzheimer's disease (AD) clinical trials. Small CDR-SB differences at the end of a trial often lead to controversy in deriving clinically meaningful interpretations.

Methods: We estimated progression-free time (PFT) participants remained at each 0.

View Article and Find Full Text PDF

The association between ischemic stroke (IS) and malignancy is well established. Cancer-related strokes are predominantly embolic and classified as embolic strokes of undetermined source (ESUS). While malignancy-associated coagulopathy represents the primary pathogenic mechanism, neoplastic embolization of circulating tumor cells is another potential etiology, particularly in cases of cardiac and pulmonary malignancies.

View Article and Find Full Text PDF

Pre-sensory (ps), peripherally-generated spontaneous activity (SA) is important for establishing basic topography of central components of sensory pathways. However, roles for psSA in sculpting connections at the single neuron level and in driving functional maturation of postsynaptic targets are difficult to isolate and therefore little explored. We capitalized on the temporal onset of cochlea-generated psSA just prior to growth of the calyx of Held (CH), the largest nerve terminal in the mammalian brain, and its well-defined circuit topography to explore the causal roles for psSA in targeted synaptogenesis and postsynaptic functional maturation.

View Article and Find Full Text PDF

Introduction: Accurate and timely diagnosis of central nervous system infections (CNSIs) is critical, yet current gold-standard techniques like lumbar puncture (LP) remain invasive and prone to delay. This study proposes a novel noninvasive framework integrating handcrafted radiomic features and deep learning (DL) to identify cerebrospinal fluid (CSF) alterations on magnetic resonance imaging (MRI) in patients with acute CNSI.

Methods: Fifty-two patients diagnosed with acute CNSI who underwent LP and brain MRI within 48 h of hospital admission were retrospectively analyzed alongside 52 control subjects with normal neurological findings.

View Article and Find Full Text PDF

This retrospective cohort study evaluated short- versus long-course antibiotics for uncomplicated infections in ambulatory solid tumor patients. Among 303 patients, outcomes were similar between groups, including infection recurrence, treatment delays, and adverse events. Short-course therapy was not associated with worse outcomes, suggesting it may be a viable alternative.

View Article and Find Full Text PDF