A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Rapid detection of BoHV-1 genomic DNA by loop-mediated isothermal amplification assay. | LitMetric

Rapid detection of BoHV-1 genomic DNA by loop-mediated isothermal amplification assay.

J Virol Methods

Department of Animal Medicine, Faculty of Veterinary Medicine, Assiut University, 71515 Assiut, Egypt. Electronic address:

Published: August 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Bovine herpes virus-1 (BoHV-1) is a serious viral pathogen of domestic and wild cattle. Herein, we report development of a new molecular diagnostic assay for rapid and sensitive detection of BoHV-1 utilizing the loop-mediated isothermal amplification (LAMP) technique. BoHV-1-LAMP assay was optimized to amplify the target DNA by incubation the Bst-DNA polymerase enzyme with a set of specially constructed six primers, based on the gE-gene of BoHV-1 virus, at 65°C for 60min. BoHV-1-LAMP products were detected by visual inspection using SYBR Green-I stain and had a ladder-like appearance by gel electrophoresis analysis. Negative results obtained with DNA from other tested fish viruses confirmed the specificity of the assay. The analytical sensitivity of the BoHV-1-LAMP assay was 1fg of BoHV-1 DNA (dilution of 10(6)). The developed assay could successfully detect BoVH-1 DNA from clinical samples. Results of this study indicate that the developed BoHV-1-LAMP is rapid and highly sensitive assay not only for detection of BoHV-1 in clinical samples, but also for differentiation between wild-type (gE-positive) and gE-negative BoHV-1 viruses, which will improve the control programs of BoHV-1 in Egypt.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jviromet.2014.04.011DOI Listing

Publication Analysis

Top Keywords

detection bohv-1
12
bohv-1
8
loop-mediated isothermal
8
isothermal amplification
8
bohv-1-lamp assay
8
clinical samples
8
assay
7
dna
5
rapid detection
4
bohv-1 genomic
4

Similar Publications