A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Reduction of voxel bleeding in highly accelerated parallel (1) H MRSI by direct control of the spatial response function. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To substantially improve spatial localization in magnetic resonance spectroscopic imaging (MRSI) accelerated by parallel imaging. This is important in order to make MRSI more reliable as a tool for clinical applications.

Methods: The sensitivity encoding acceleration technique with spatial overdiscretization is applied for the reconstruction of parallel MRSI. In addition, the spatial response function is optimized by minimizing its deviation from a previously chosen target function. This modified minimum-norm sensitivity encoding-MRSI reconstruction approach is applied in this article for in vivo pulse-acquire MRSI of human brain at 7T with simulated acceleration factors of 2, 4, and 9 as well as actual 4-fold accelerated MRSI.

Results: The sidelobes of the spatial response function are significantly suppressed, which reduces far-reaching voxel bleeding. At the same time, the major enlargement of the effective voxel size, which would be introduced by conventional k-space apodization methods, is largely avoided. Regularization allows for a practical trade-off between noise minimization, effective voxel size, and unaliasing. Although not aiming at increasing the nominal spatial resolution, a better spatial specificity is achieved.

Conclusion: Simultaneous suppression of short- and far-reaching voxel bleeding in MRSI is analyzed and reconstruction of highly accelerated parallel in vivo MRSI is demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25185DOI Listing