The impact of stormwater source-control strategies on the (low) flow regime of urban catchments.

Water Sci Technol

Department of Civil Engineering and Monash Water for Liveability (CRC for Water Sensitive Cities), Monash University, Victoria 3800, Australia E-mail: Department of Resource Management and Geography, The University of Melbourne, 500 Yarra Boulevard, Burnley, Victoria 3121, A

Published: April 2014


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Stormwater management strategies increasingly recognise the need to emulate the pre-development flow regime, in addition to reducing pollutant concentrations and loads. However, it is unclear whether current design approaches for stormwater source-control techniques are effective in restoring the whole flow regime, and in particular low flows, towards their pre-development levels. We therefore modelled and compared a range of source-control stormwater management strategies, including some specifically tailored towards enhancing baseflow processes. The strategies were assessed based on the total streamflow volume and three low flow metrics. Strategies based on harvesting tanks showed much greater volume reduction than those based on raingardens. Strategies based on a low flow rate release, aimed at mimicking natural baseflow, failed to completely restore the baseflow regime. We also found that the sensitivity of the low flow metrics to the proportion of catchment treated varied amongst metrics, illustrating the importance of metrics selection in the assessment of stormwater strategies. In practice, our results suggest that realistic scenarios using low flow release from source-control techniques may not be able to fully restore the low flow regime, at least for perennial streams. However, a combination of feasibly-sized tanks and raingardens is likely to restore the baseflow regime to a great extent, while also benefitting water quality through the retention and filtration processes.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2013.772DOI Listing

Publication Analysis

Top Keywords

low flow
24
flow regime
16
stormwater source-control
8
flow
8
stormwater management
8
management strategies
8
source-control techniques
8
flow metrics
8
strategies based
8
restore baseflow
8

Similar Publications

Angiotensin II (Ang II) releases inflammatory mediators from several cell types. The objective of this study was to investigate the potential of Ang II to induce mRNA expression of inflammatory mediators in primary cultured fibroblast-like cells isolated from gingival and periodontal ligament tissues. A synergistic effect of co-treatment with Ang II and Interleukin-1β (IL1β) on the mRNA expression of inflammatory mediators was explored.

View Article and Find Full Text PDF

The purpose of our review was to group the evidence and attempt to provide a consensus on the behavior of salivary flow rate in patients with Down syndrome. Observational studies evaluating salivary flow rate in children and teenagers with Down syndrome compared with non-syndrome individuals were selected. Ten sources of information were researched.

View Article and Find Full Text PDF

Despite recent progress within the field of immuno-oncology, immune suppression in the tumor microenvironment, defective antigen presentation, and low levels of tumor-specific T cells are key limitations of current cancer immunotherapies. CD40-targeting immunotherapies hold promises for addressing these limitations across solid tumors. Here, we describe ATOR-4066, a bispecific antibody that targets CD40 and CEACAM5 developed for immunotherapy of cancer using the Neo-X-Prime platform.

View Article and Find Full Text PDF

Fluorescent proteins (FPs) are commonly used as reporters to examine intracellular genetic, molecular, and biochemical status. Flow cytometry is a powerful technique for accurate quantification of single-cell fluorescent levels. Here, we characterize green, red, and blue FPs for use in yeast .

View Article and Find Full Text PDF

Background: The diagnostic accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of lymphoma has a low overall sensitivity. The lack of tissue architecture obtained by cytological needles decreases the diagnostic accuracy for diagnosis and subtyping of and relapsed mediastinal lymphomas. This study compares the sensitivity of EBUS-TBNA and endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy (EBUS-TMC) for both initial lymphoma diagnosis and recurrent cases, analyses safety, and evaluates the number of mediastinoscopies that could potentially be avoided due to this novel technique.

View Article and Find Full Text PDF