A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Inter & intra-observer reliability of grading ultrasound videoclips with hand pathology in rheumatoid arthritis by using non- sophisticated internet tools (LUMINA study). | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aim: To evaluate the inter- and intraobserver agreement of a group of European rheumatologist ultrasonographers in grading musculoskeletal ultrasound videoclips posted on the Internet by using a non-sophisticated electronic environment.

Methods: Forty short movie clips (less than 30 secs) were made available over the Internet to all participants. Normal and pathological RA hand joints and tendons were included in the movie clips. In the first phase 30 investigators from European countries were invited to evaluate the clips and to interpret/grade them. No instruction session was held prior to the initiation of the study. For synovitis the requested scoring system included 0 to3 grades and for tenosynovitis a binary variable 0/1; separate evaluations were performed for gray scale (GS) and Power Doppler (PD) examinations. In the second phase the responders were asked to grade the same clips in a different order without having access to their first grading scale. Light's k and Cohen's k were used to analyse inter- and intraobserver reliability.

Results: Twenty two European rheumatologists agreed to finalise both study phases. Mean Cohen's κ for intraobserver reliability was 0.614/0.689 for tenosynovitis GS/PD and 0.523/0.621 for synovitis GS/PD. Light's k for interobserver reliability was 0.503 for tenosynovitis evaluation and 0.455 for global (synovitis and tenosynovitis) evaluation. Mean global overall agreement was 84.95% (90.2% for global synovitis).

Conclusions: An over-the-net US evaluation and grading has shown moderate to good reliability. The results could be improved if a training session is added at the beginning of the study.

Download full-text PDF

Source
http://dx.doi.org/10.11152/mu.2014.2066.161.vv1fb2DOI Listing

Publication Analysis

Top Keywords

ultrasound videoclips
8
inter- intraobserver
8
movie clips
8
tenosynovitis evaluation
8
inter intra-observer
4
reliability
4
intra-observer reliability
4
grading
4
reliability grading
4
grading ultrasound
4

Similar Publications