98%
921
2 minutes
20
Objective: To investigate the correlative anterior segment parameters of positive darkroom provocative test in patients with narrow anterior chamber angles.
Methods: It was a retrospective case series study. Two hundred and sixty patients [36 males and 224 females, mean age (59.6 ± 9.3) years] with narrow anterior chamber angles underwent darkroom provocative test and UBM scan were analyzed retrospectively. Anterior segment parameters including anterior chamber depth (ACD), pupil diameter (PD), lens vault (LV), peripheral iris thickness (IT), iris convex (IC), anterior chamber angle open distance (AOD), trabecular-meshwork ciliary process angle (TCPA) and the number of appositional angle closure (NPAC) were quantitatively analyzed. Correlative factors of positive results were analysis by both single factor and multiple-factor analysis.
Results: Seventy-one (27.3%) of the 260 patients had positive results in the darkroom provocative test. Males (15 out of 36) had statistically higher positive result rate than females (56 out of 224) (M: 41.7% vs. F:25.0%, χ(2) = 4.340, P = 0.037). In single factor analysis, male (OR = 2.14), AOD (OR = 0.98), IT (OR = 1.68) and NPAC (OR = 2.24) were correlative factors for positive results. In multiple-factor analysis, only IT (OR = 1.47) and NPAC (OR = 1.70) were independent risk factors of positive results.
Conclusions: Positive darkroom provocative test is correlated to parameters of anterior chamber angle and iris, while IT and NPAC are independent correlative factors in patients with narrow anterior chamber angle.
Download full-text PDF |
Source |
---|
Retina
June 2025
Ophthalmology Department 5, National Hospital 15-20, Paris, France.
Clin Exp Ophthalmol
September 2025
Department of Neurosurgery, National Neuroscience Institute, Singapore, Singapore.
Background: To describe clinical features, risk factors and outcomes of out-of-the-bag (OTB) intraocular lens (IOL) dislocation in dead bag syndrome (DBS).
Methods: Retrospective review of a single-surgeon series of eyes with IOLs that developed OTB IOL dislocation, managed at Singapore National Eye Centre (January 2014-December 2021), with a minimum of 6 months of follow-up. Eyes with OTB IOL dislocation following secondary IOL implantation and intraoperative capsule complications were excluded.
Zhonghua Yan Ke Za Zhi
September 2025
Beijing Aier-Intech Eye Hospital, Beijing 100021, China.
Two patients (a 7-year-old female and a 61-year-old male) had poor intraocular pressure control after XEN gel stent implantation. During the process of filtering bleb repair, the XEN gel implant retreated into the anterior chamber, and the limbal and corneal incisions were made. After the implant in the anterior chamber was taken out, it was implanted into the anterior chamber again from the original scleral tunnel for the female patient, while it was re-punctured into the anterior chamber with a 1-ml syringe needle at another site for the male patient.
View Article and Find Full Text PDFZhonghua Yan Ke Za Zhi
September 2025
Ophthalmology Medical Center, The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory for the Prevention and Treatment of Major Blinding Eye Diseases, Chongqing Branch (Municipality Division) of National Clinical Research Centre for Ocular Diseases, Chongqing 400016,
To explore optimized protocols for paraffin section preparation of the eyeball to enhance the histological visualization of key ocular structures. It was an experimental research, conducted from September 2022 to September 2024. The first experiment involved 18 porcine eyeballs, which were divided into five groups (six subgroups) by the random number table method.
View Article and Find Full Text PDFAm J Ophthalmol
September 2025
Dean McGee Eye Institute, University of Oklahoma, Oklahoma City, Oklahoma, USA. Electronic address:
Purpose: To compare refractive prediction accuracy using simulated keratometry (SimK) measurements obtained from a Scheimpflug tomographer (Pentacam AXL, Oculus) versus keratometry (K) measurements obtained from an optical biometer utilizing telecentric keratometry (IOLMaster 700 (IOLM700), Carl Zeiss Meditec AG) applied to modern IOL power calculation formulas.
Design: Retrospective accuracy and validity analysis METHODS: Setting: Private practice center STUDY POPULATION: Five hundred eighty-nine eyes with preoperative SimK and K measurements undergoing phacoemulsification and implantation of monofocal IOL (Clareon SY60WF IOL, Alcon Laboratories, Inc.).