98%
921
2 minutes
20
A novel SiX-dipropargyl glycerol scaffold (X: H, F, or (18) F) was developed as a versatile prosthetic group that provides technical advantages for the preparation of dimeric radioligands based on silicon fluoride acceptor pre- or post-labeling with fluorine-18. Rapid conjugation with the prosthetic group takes place in microwave-assisted click conjugation under mild conditions. Thus, a bivalent homodimeric SiX-dipropargyl glycerol derivatized radioligand, [(18) F]BMPPSiF, with enhanced affinity was developed by using click conjugation. High uptake of the radioligand was demonstrated in 5-HT1A receptor-rich regions in the brain with positron emission tomography. Molecular docking studies (rigid protein-flexible ligand) of BMPPSiF and known antagonists (WAY-100635, MPPF, and MefWAY) with monomeric, dimeric, and multimeric 5-HT1A receptor models were performed, with the highest G score obtained for docked BMPPSiF: -6.766 as compared with all three antagonists on the monomeric model. Multimeric induced-fit docking was also performed to visualize the comparable mode of binding under in vivo conditions, and a notably improved G score of -8.455 was observed for BMPPSiF. These data directly correlate the high binding potential of BMPPSiF with the bivalent binding mode obtained in the biological studies. The present study warrants wide application of the SiX-dipropargyl glycerol prosthetic group in the development of ligands for imaging with enhanced affinity markers for specific targeting based on peptides, nucleosides, and lipids.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/cmdc.201300458 | DOI Listing |
J Prosthet Dent
September 2025
Associate Professor, School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan, ROC. Electronic address:
Statement Of Problem: While valued for their durability in dental prosthetics, polyaryletherketone (PAEK) materials, known for their chemical inertness and low surface energy, pose significant challenges in achieving durable adhesion to resin cements, a critical factor for the long-term success of dental restorations.
Purpose: This study evaluates the novel application of a methyl methacrylate-urethane dimethacrylate (MMA-UDMA) bonding primer following handheld nonthermal plasma (HNP) treatment to enhance the bonding performance and aging durability of PAEK materials with varying microfiller compositions, addressing the persistent challenge of achieving long-term adhesion in dental restorations.
Material And Methods: Three PAEK types, ceramic-filled polyetheretherketone (PEEK), titanium dioxide-filled polyetherketoneketone (PEKK), and PEEK with disk shape (Ø10×2.
J Prosthet Dent
September 2025
Full Professor, School of Mechanical Engineering, Universidad Industrial de Santander, Bucaramanga, Colombia. Electronic address:
Statement Of Problem: Although custom temporomandibular joint (TMJ) prostheses manufactured via computer-aided design and manufacturing (CAD-CAM) and produced through 3-dimensional (3D) printing or computer numerical control (CNC) allow for sagittal curvature adjustments in the glenoid fossa, their design remains unregulated by the Food and Drug Administration. Consequently, the geometry is determined largely by the engineer's discretion, with limited biomechanical evidence to guide these decisions. The lack of validation regarding how sagittal curvature influences joint stress distribution under various anatomical and functional conditions represents a gap in current knowledge that warrants investigation.
View Article and Find Full Text PDFJ Prosthet Dent
September 2025
Assistant Professor, Department of Prosthetic Dentistry, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France; and Researcher, University of Bordeaux, CNRS, Ministry of Culture, PACEA, UMR 5199, Pessac, France. Electronic address:
Statement Of Problem: The reproducibility of positioning the maxillary occlusal plane in an articulator with a facebow remains debated. Its clinical use is widespread, yet its reliability and clinical outcomes compared to other transfer methods under standardized conditions remain uncertain.
Purpose: The purpose of this in vitro study was to compare the intra-operator reproducibility of maxillary positioning on an articulator using a facebow compared to a standardized transfer table.
J Prosthodont
September 2025
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.
Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.
Int J Oral Implantol (Berl)
September 2025
Purpose: To compare the accuracy of static guided surgery using a pilot drill guide and dynamic guided surgery for dental implant placement.
Materials And Methods: Partially edentulous adult patients requiring implant placement were randomly assigned to either the static guided surgery group using a pilot drill guide or the dynamic guided surgery group. Digital implant planning was conducted using intraoral scans and CBCT with planning software to determine the optimal prosthetic position.