Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Global longitudinal strain (GLS) derived from two-dimensional speckle-tracking is an emerging technology, but lack of industry standards limits its application. Prior studies support using this tool to identify subclinical disease through serial changes, but the variability introduced by a change in vendor or reader is not well defined.

Methods: Fifty study subjects were prospectively identified to include four subgroups to ensure a broad range of GLS: normal (n = 20), left ventricular hypertrophy (n = 10), ST-segment elevation myocardial infarction (n = 10), and systolic heart failure (n = 10). Raw data were obtained using equipment from two vendors during the same session, and GLS was analyzed using an offline workstation. Intraobserver and interobserver variation was measured using correlation coefficients, intraclass correlation coefficients, and Bland-Altman plots.

Results: GLS measurements were highly reproducible by the same reader or a different reader using vendor 1 and vendor 2 or comparing vendors (correlation coefficients and intraclass correlation coefficients ≥ 0.95). However, the Bland-Altman plots suggested that the variation in repeat GLS measurements may range from ± 2% to ± 5% on the basis of a change in vendor, reader, or both.

Conclusions: The expected variation in GLS measurements associated with a change in vendor, reader, or both should be considered when making conclusions about significant changes in serial measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2013.08.021DOI Listing

Publication Analysis

Top Keywords

correlation coefficients
16
change vendor
12
vendor reader
12
gls measurements
12
left ventricular
8
global longitudinal
8
longitudinal strain
8
coefficients intraclass
8
intraclass correlation
8
gls
6

Similar Publications

To develop and validate a deep-learning-based algorithm for automatic identification of anatomical landmarks and calculating femoral and tibial version angles (FTT angles) on lower-extremity CT scans. In this IRB-approved, retrospective study, lower-extremity CT scans from 270 adult patients (median age, 69 years; female to male ratio, 235:35) were analyzed. CT data were preprocessed using contrast-limited adaptive histogram equalization and RGB superposition to enhance tissue boundary distinction.

View Article and Find Full Text PDF

Polymorphic two-dimensional (2D) transition metal dichalcogenides (TMDCs) exhibit diverse properties for optoelectronic applications. Here, utilizing phase-engineered MoTe as a prototypical platform, we comprehensively explored its ultrafast and nonlinear optical properties to complete the fundamental framework of phase-dependent optical phenomena in 2D TMDCs. Starting with the phase-selective synthesis of 2H- and 1T'-MoTe with tailored thicknesses, we revealed their distinct photocarrier relaxation mechanisms using intensive power-/temperature-/thickness-dependent transient absorption spectra (TAS).

View Article and Find Full Text PDF

Background: Hounsfield units (HU) on computed tomography (CT) are strongly correlated with bone mineral density (BMD) and may aid in osteoporosis screening. However, there is no standardized method for assessing bone density in displaced femoral head fractures. This study aimed to measure HU values in the femoral head using preoperative post-fracture CT images of patients with intertrochanteric femoral fractures and investigate whether it correlated with BMD measured by dual-energy X-ray absorptiometry (DXA).

View Article and Find Full Text PDF

Objective: This study validates the previously tested Screening for Poverty And Related social determinants to improve Knowledge of and access to resources ('SPARK Tool') against comparison questions from well-established national surveys (Post Survey Questionnaire (PSQ)) to inform the development of a standardised tool to collect patients' demographic and social needs data in healthcare.

Design: Cross-sectional study.

Setting: Pan-Canadian study of participants from four Canadian provinces (SK, MB, ON and NL).

View Article and Find Full Text PDF

Assessment of GFR Estimation Methods in Patients with Obesity.

J Clin Endocrinol Metab

September 2025

AURA (Association pour l'Utilisation du Rein Artificiel dans la région parisienne), F-75014 Paris, France.

Purpose: Obesity is an independent risk factor for chronic kidney disease, and accurate estimation of the glomerular filtration rate (GFR) is crucial. However, limited data are available on the performance of the European Kidney Function Consortium (EKFC) equation in individuals with overweight or obesity. We evaluated the performance of the EKFC equation by comparing its estimated GFR (eGFR) to values obtained from the 2021 Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation and machine learning (ML) models, using measured GFR (mGFR, obtained via plasma iohexol clearance) as a reference standard in a cohort of patients with overweight or obesity.

View Article and Find Full Text PDF