Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
An on-line two-dimensional liquid chromatography method was developed for comprehensive lipid profiling by coupling strong anion exchange (SAX) and nanoflow reversed-phase liquid chromatography (nRPLC) prior to electrospray ionization-tandem mass spectrometry (2D-SAX/nRPLC-ESI-MS/MS). Lipids can be classified into four different types according to the electrical propensities of the lipids: anionic, weak anionic, neutral polar, and special lipids. In 2D-SAX/nRPLC, various lipids can be fractionated in the first dimension (SAX: 5 μm to 100 Å, 5.0 cm × 75 μm i.d.) by step elution (methanol and salt solution), followed by the molecular separation of lipids in the second dimension (RP: 3 μm to 100 Å, 7.0 cm × 75 μm i.d.) with binary gradient LC. Since the elution of lipids from SAX can be achieved with a very small volume of eluent delivered from an autosampler, it can be simply implemented with an LC-ESI-MS instrument for full automation, and the salt step elution, including the two-step injection procedure, can be used for the selective analysis of the desired lipid fraction. For nRPLC-ESI-MS/MS run in either positive or negative ion mode, a common ionization modifier (0.05% ammonium hydroxide with 5mM ammonium formate) was introduced into the binary mobile phase solutions so that 2D-LC-MS could be operated in both ion modes without changing the mobile phase solutions. The developed on-line 2D-SAX/nRPLC-ESI-MS/MS was evaluated with 22 different standard lipids for the optimization of the salt step elution and was applied to a healthy human plasma lipid extract, resulting in the identification of a total of 303 plasma lipids, including 14 different classes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2013.08.069 | DOI Listing |