A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Absolute quantitation of immunoglobulin G and its glycoforms using multiple reaction monitoring. | LitMetric

Absolute quantitation of immunoglobulin G and its glycoforms using multiple reaction monitoring.

Anal Chem

Department of Chemistry, University of California, One Shields Avenue, Davis, California, 95616, United States.

Published: September 2013


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Studies aimed toward glycan biomarker discovery have focused on glycan characterization by the global profiling of released glycans. Site-specific glycosylation analysis is less developed but may provide new types of biomarkers with higher sensitivity and specificity. Quantitation of peptide-conjugated glycans directly facilitates the differential analysis of distinct glycoforms associated with specific proteins at distinct sites. We have developed a method using MRM to monitor protein glycosylation normalized to absolute protein concentrations to examine quantitative changes in glycosylation at a site-specific level. This new approach provides information regarding both the absolute amount of protein and the site-specific glycosylation profile and will thus be useful to determine if altered glycosylation profiles in serum/plasma are due to a change in protein glycosylation or a change in protein concentration. The remarkable sensitivity and selectivity of MRM enable the detection of low abundance IgG glycopeptides, even when IgG was digested directly in serum with no cleanup prior to the liquid chromatography. Our results show a low limit of detection of 60 amol and a wide dynamic range of 3 orders magnitude for IgG protein quantitation. The results show that IgG glycopeptides can be analyzed directly from serum (without enrichment) and yield more accurate abundances when normalized to the protein content. This report represents the most comprehensive study so far of the use of multiple reaction monitoring for the quantitation of glycoproteins and their glycosylation patterns in biofluids.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3857154PMC
http://dx.doi.org/10.1021/ac4009995DOI Listing

Publication Analysis

Top Keywords

multiple reaction
8
reaction monitoring
8
site-specific glycosylation
8
protein glycosylation
8
change protein
8
igg glycopeptides
8
directly serum
8
glycosylation
7
protein
7
absolute quantitation
4

Similar Publications