98%
921
2 minutes
20
The present article reports a case involving a 29-year-old man who developed severe cardiac failure (New York Heart Association class IV). He had a complex surgical history, beginning with the repair of an anterior sinus of Valsalva aneurysm and closure of a ventricular septal defect at eight months of age. His residual Valsalva aneurysm and mixed aortic valve disease necessitated mechanical aortic valve replacement at 14 years of age. One year later, he developed coagulase-negative staphylococcal prosthetic valve infective endocarditis, necessitating an additional replacement of his valve with a pulmonary homograft. Subsequent follow-up revealed a dilated ascending aorta (6 cm) and increased regurgitation through his homograft, with significant dilation of the left ventricle. At 20 years of age, he underwent excision of the aneurysmal ascending aorta and arch of the aorta, and the aortic valve was replaced with a 29 mm bioprosthetic valve. This proved satisfactory for nine years until he presented at Guy's and St Thomas' National Health Services Foundation Trust (London, United Kingdom) with severe aortic regurgitation. His logistic EuroScore was 5.9 and Parsonnet score was 17 but, due to extensive previous surgery, he was considered and accepted for transcatheter aortic valve implantation. A 29 mm Edwards Sapien valve (Edwards Lifesciences, USA) was successfully implanted using a valve-in-valve procedure. The patient remained well and symptom free at early follow-up. Technical aspects of this complex adult congenital case that, to the authors' knowledge is the youngest case of transcatheter aortic valve implantation and the first 29 mm valve-in-valve procedure, are discussed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3627286 | PMC |
Multimed Man Cardiothorac Surg
September 2025
Department of Cardiothoracic Surgery, Royal Children’s Hospital, Melbourne, Australia
The patient had rheumatic heart disease, which resulted in severe aortic and mitral valve regurgitation. Repair of both valves was performed at 9 years of age. During surgery, the retracted aortic valve cusps required extension with bovine pericardial patches and suture reduction annuloplasty, and the mitral valve was repaired using a Cosgrove-Edwards (Edwards Lifesciences LLC, Irvine, CA) annuloplasty band.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
September 2025
Division of Cardiac Surgery, Department of Surgery, Western University, London Health Science Centre, London, Ontario, Canada.
J Neuroendovasc Ther
August 2025
Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Hiroshima, Japan.
Objective: Endovascular treatment of cerebrovascular diseases can be challenging in patients with difficult access routes. We describe a turn-over technique using a balloon guiding catheter (BGC) via the transfemoral approach to perform neuroendovascular treatment.
Case Presentation: An 80-year-old female with a recurrent right middle cerebral artery (MCA) aneurysm after coil embolization underwent successful stent-assisted coiling via the transfemoral approach.
J Geriatr Cardiol
August 2025
Department of Bachelor of Medicine, Bachelor of Surgery, Sindh Medical College, Jinnah Sindh Medical University, Karachi, Pakistan.
Cureus
August 2025
Acute Internal Medicine, University Hospitals of North Midland, Royal Stoke University Hospital, Stoke-on-Trent, GBR.
Infective endocarditis is a potentially fatal condition that can present with non-specific symptoms and rare hematologic manifestations, posing significant diagnostic challenges. We report a compelling case of a 67-year-old male with a history of type 2 diabetes, hypertension, and hyperlipidemia who sought medical attention for a five-month history of progressive iron deficiency anemia, accompanied by weight loss, fatigue, and vague constitutional symptoms. Initial extensive workup, including computed tomography of the thorax, abdomen, and pelvis, gastroscopy, colonoscopy, and transthoracic echocardiography, failed to identify an underlying cause.
View Article and Find Full Text PDF