Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Context: In 2013 the high throughput technology known as Tissue Micro Array (TMA) will be fifteen years old. Its elements (design, construction and analysis) are intuitive and the core histopathology technique is unsophisticated, which may be a reason why has eluded a rigorous scientific scrutiny. The source of errors, particularly in specimen identification and how to control for it is unreported. Formal validation of the accuracy of segmenting (also known as de-arraying) hundreds of samples, pairing with the sample data is lacking.

Aims: We wanted to address these issues in order to bring the technique to recognized standards of quality in TMA use for research, diagnostics and industrial purposes.

Results: We systematically addressed the sources of error and used barcode-driven data input throughout the whole process including matching the design with a TMA virtual image and segmenting that image back to individual cases, together with the associated data. In addition we demonstrate on mathematical grounds that a TMA design, when superimposed onto the corresponding whole slide image, validates on each and every sample the correspondence between the image and patient's data.

Conclusions: High throughput use of the TMA technology is a safe and efficient method for research, diagnosis and industrial use if all sources of errors are identified and addressed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551499PMC
http://dx.doi.org/10.4103/2153-3539.104904DOI Listing

Publication Analysis

Top Keywords

design construction
8
high throughput
8
tma
5
tissue microarray
4
design
4
microarray design
4
construction scientific
4
scientific industrial
4
industrial diagnostic
4
diagnostic context
4

Similar Publications

Importance: Stoma reversal is associated with few complications. However, recent studies show that 1 in 3 patients develop an incisional hernia, for which half of the patients receive surgical correction.

Objective: To investigate whether prophylactic synthetic mesh placement in the retromuscular space during stoma reversal reduces the rate of stomal site incisional hernias.

View Article and Find Full Text PDF

Design and synthesis of novel indolinone Aurora B kinase inhibitors based on fragment-based drug discovery (FBDD).

Mol Divers

September 2025

State Key Laboratory Basis of Xinjiang Indigenous Medicinal Plants Resource Utilization, Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi, 830011, Xinjiang, China.

Aurora kinases are a group of serine/threonine kinases essential for cell mitosis, comprising Aurora A, B, and C. However, the Aurora B is overexpressed in multiple tumors and the aurone has been proved to exhibit potent inhibitory activity against Aurora B kinase by our group. The indolinone was considered as an aurone scaffold hopping analog, and the indolinone-based Aurora B inhibitor library (3577 molecules) was constructed by FBDD strategy.

View Article and Find Full Text PDF

A fundamental question in the field of molecular computation is what computational tasks a biochemical system can carry out. In this work, we focus on the problem of finding the maximum likelihood estimate (MLE) for log-affine models. We revisit a construction due to Gopalkrishnan of a mass-action system with the MLE as its unique positive steady state, which is based on choosing a basis for the kernel of the design matrix of the model.

View Article and Find Full Text PDF

Synchrotron light sources are powerful platforms for cutting-edge, multidisciplinary research, with dozens currently in operation, construction or commissioning worldwide. It is widely recognized that different research areas have specific demands for source capabilities. For the majority of synchrotron facilities, delivering high-brightness, high-flux synchrotron radiation stably through high-current electron beams is the primary mode of operation.

View Article and Find Full Text PDF

Background: Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently, a dynamic tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation.

View Article and Find Full Text PDF