A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Sympathetic neural and hemodynamic responses to upright tilt in patients with pulsatile and nonpulsatile left ventricular assist devices. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Left ventricular assist devices (LVADs) are now widely accepted as an option for patients with advanced heart failure. First-generation devices were pulsatile, but they had poor longevity and durability. Newer generation devices are nonpulsatile and more durable, but remain associated with an increased risk of stroke and hypertension. Moreover, little is understood about the physiological effects of the chronic absence of pulsatile flow in humans.

Methods And Results: We evaluated patients with pulsatile (n=6) and nonpulsatile (n=11) LVADs and healthy controls (n=9) during head-up tilt while measuring hemodynamics and muscle sympathetic nerve activity. Patients with nonpulsatile devices had markedly elevated supine and upright muscle sympathetic nerve activity (mean±SD, 43±15 supine and 60±21 bursts/min at 60° head-up tilt) compared with patients with pulsatile devices (24±7 and 35±8 bursts/min; P<0.01) and controls (11±6 and 31±6 bursts/min; P<0.01); however, muscle sympathetic nerve activity was not different between patients with pulsatile flow and controls (P=0.34). Heart rate, mean arterial pressure, and total peripheral resistance were greater, whereas cardiac output was smaller, in LVAD patients compared with controls in both supine and upright postures. However, these hemodynamic variables were not significantly different between patients with pulsatile and nonpulsatile flow.

Conclusions: Heart failure patients with continuous, nonpulsatile LVADs have marked sympathetic activation, which is likely due, at least in part, to baroreceptor unloading. We speculate that such chronic sympathetic activation may contribute to, or worsen end-organ diseases, and reduce the possibility of ventricular recovery. Strategies to provide some degree of arterial pulsatility, even in continuous flow LVADs may be necessary to achieve optimal outcomes in these patients.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCHEARTFAILURE.112.969873DOI Listing

Publication Analysis

Top Keywords

patients pulsatile
12
left ventricular
8
ventricular assist
8
assist devices
8
head-up tilt
8
muscle sympathetic
8
sympathetic nerve
8
nerve activity
8
devices
6
patients
5

Similar Publications