Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This work explores the feasibility and impact of including both the motion correction and the image registration transformation parameters from positron emission tomography (PET) image space to magnetic resonance (MR), or stereotaxic, image space within the system matrix of PET image reconstruction. This approach is motivated by the fields of neuroscience and psychiatry, where PET is used to investigate differences in activation patterns between different groups of participants, requiring all images to be registered to a common spatial atlas. Currently, image registration is performed after image reconstruction which introduces interpolation effects into the final image. Furthermore, motion correction (also requiring registration) introduces a further level of interpolation, and the overall result of these operations can lead to resolution degradation and possibly artifacts. It is important to note that performing such operations on a post-reconstruction basis means, strictly speaking, that the final images are not ones which maximize the desired objective function (e.g. maximum likelihood (ML), or maximum a posteriori reconstruction (MAP)). To correctly seek parameter estimates in the desired spatial atlas which are in accordance with the chosen reconstruction objective function, it is necessary to include the transformation parameters for both motion correction and registration within the system modeling stage of image reconstruction. Such an approach not only respects the statistically chosen objective function (e.g. ML or MAP), but furthermore should serve to reduce the interpolation effects. To evaluate the proposed method, this work investigates registration (including motion correction) using 2D and 3D simulations based on the high resolution research tomograph (HRRT) PET scanner geometry, with and without resolution modeling, using the ML expectation maximization (MLEM) reconstruction algorithm. The quality of reconstruction was assessed using bias-variance and root mean squared error analyses, comparing the proposed method to conventional post-reconstruction registration methods. An overall reduction in bias (for a cold region: from 41% down to 31% (2D) and 97% down to 65% (3D), and for a hot region: from 11% down to 8% (2D) and from 16% down to 14% (3D)) and in root mean squared error analyses (for a cold region: from 43% to 37% (2D) and from 97% to 65% (3D), and for a hot region: from 11% to 9% (2D) and from 16% down to 14% (3D)) in reconstructed regional mean activities (full regions of interest; all with statistical significance: p < 5 × 10(-10)) is found when including the motion correction and registration in the system matrix of the MLEM reconstruction, with resolution modeling. However, this improvement in performance comes with an extra computational cost of about 40 min. In this context, this work constitutes an important step toward the goal of estimating parameters of interest directly from the raw Poisson-distributed PET data, and hence toward the complete elimination of post-processing steps.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/58/1/105DOI Listing

Publication Analysis

Top Keywords

motion correction
24
image reconstruction
16
including motion
16
pet image
12
correction registration
12
spatial atlas
12
objective function
12
reconstruction
9
registration
8
image
8

Similar Publications

Background: Evidence supporting surgery in elderly patients with distal radius fractures is limited, but displaced fractures may benefit from surgery. This study aimed to determine whether casting is noninferior to surgery for patients aged 65 years or older with substantially displaced intra-articular (AO type C) distal radius fractures.

Methods: This multicenter randomized controlled noninferiority trial included 138 patients (mean age 76 years, SD 6.

View Article and Find Full Text PDF

Full Free-Breathing Cardiac MRI: Enhancing Efficiency and Image Quality in Clinical Practice.

J Cardiovasc Magn Reson

September 2025

Department of Magnetic Resonance Imaging, Fuwai Hospital and National Center for Cardiovascular Diseases, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100037, China; Key Laboratory of Cardiovascular Imaging, Chinese Academy of Medical Sciences, Beijing 100730, China.

Background: Conventional cardiac magnetic resonance (CMR) examinations require patients to repeatedly hold their breath, which can reduce examination efficiency and pose challenges for patients unable to do so. This study aimed to demonstrate the feasibility and effectiveness of a full free-breathing CMR protocol in clinical practice.

Methods: Patients prospectively enrolled in this study underwent a full free-breathing CMR exam on a 3T scanner between June 1 and June 30, 2024.

View Article and Find Full Text PDF

Cardiovascular magnetic resonance imaging: Principles and advanced techniques.

Prog Nucl Magn Reson Spectrosc

September 2025

School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Institute for Biological and Medical

Cardiovascular magnetic resonance (CMR) imaging is an established non-invasive tool for the assessment of cardiovascular diseases, which are the leading cause of death globally. CMR provides dynamic and static multi-contrast and multi-parametric images, including cine for functional evaluation, contrast-enhanced imaging and parametric mapping for tissue characterization, and MR angiography for the assessment of the aortic, coronary and pulmonary circulation. However, clinical CMR imaging sequences still have some limitations such as the requirement for multiple breath-holds, incomplete spatial coverage, complex planning and acquisition, low scan efficiency and long scan times.

View Article and Find Full Text PDF

Purpose: To develop a rapid 2D free-running myocardial mapping technique that is robust to through-plane respiratory motion.

Methods: A free-running golden angle radial sequence consisting of encoding and self-navigated auto motion calibration (SNAC) was developed. The encoding adopted inversion recovery (IR) prepared interleaved multi-slice acquisition with optimized inter-slice gap to ensure a uniform excitation of the middle slice regardless of through-plane respiratory motion.

View Article and Find Full Text PDF

In March of 2025, 145 attendees convened at the Hub for Clinical Collaboration of the Children's Hospital of Philadelphia for the inaugural International Society for Magnetic Resonance in Medicine (ISMRM) Body MRI Study Group workshop entitled "Body MRI: Unsolved Problems and Unmet Needs." Approximately 24% of the attendees were MD or MD/PhD's, 45% were PhD's, and 30% were early-career trainees and postdoctoral associates. Among the invited speakers and moderators, 28% were from outside the United States, with a 40:60% female-to-male ratio.

View Article and Find Full Text PDF