98%
921
2 minutes
20
Magnetic resonance imaging (MRI) is a widely used method for non-invasive study of the structure and function of the human brain. Increasing magnetic field strengths enable higher resolution imaging; however, long scan times and high motion sensitivity mean that image quality is often limited by the involuntary motion of the subject. Prospective motion correction is a technique that addresses this problem by tracking head motion and continuously updating the imaging pulse sequence, locking the imaging volume position and orientation relative to the moving brain. The accuracy and precision of current MR-compatible tracking systems and navigator methods allows the quantification and correction of large-scale motion, but not the correction of very small involuntary movements in six degrees of freedom. In this work, we present an MR-compatible tracking system comprising a single camera and a single 15 mm marker that provides tracking precision in the order of 10 m and 0.01 degrees. We show preliminary results, which indicate that when used for prospective motion correction, the system enables improvement in image quality at both 3 T and 7 T, even in experienced and cooperative subjects trained to remain motionless during imaging. We also report direct observation and quantification of the mechanical ballistocardiogram (BCG) during simultaneous MR imaging. This is particularly apparent in the head-feet direction, with a peak-to-peak displacement of 140 m.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3492340 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0048088 | PLOS |
Phys Med
September 2025
Department of Biomedical Technology, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 8, 33720 Tampere, Finland; School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg, Jan Smutslaan 1, 2050 Braamfontein, South Africa.
Background And Objective: Correction of rotational setup errors by tilting the treatment couch improves target dose accuracy and prevents healthy tissue overdosage in external beam radiotherapy. However, couch tilts may cause secondary patient motion. This study aimed to quantify the secondary motion caused by pitch and roll corrections and to evaluate the feasibility of surface imaging for detecting the secondary motion in pelvic radiotherapy.
View Article and Find Full Text PDFPhys Eng Sci Med
September 2025
Department of Radiology, Otaru General Hospital, Otaru, Hokkaido, Japan.
In lung CT imaging, motion artifacts caused by cardiac motion and respiration are common. Recently, CLEAR Motion, a deep learning-based reconstruction method that applies motion correction technology, has been developed. This study aims to quantitatively evaluate the clinical usefulness of CLEAR Motion.
View Article and Find Full Text PDFJ Neurosci
September 2025
Jefferson Moss Rehabilitation Research Institute, Thomas Jefferson University, Elkins Park, PA 19027.
Tool use is a complex motor planning problem. Prior research suggests that planning to use tools involves resolving competition between different tool-related action representations. We therefore reasoned that competition may also be exacerbated with tools for which the motions of the tool and the hand are incongruent (e.
View Article and Find Full Text PDFJB JS Open Access
September 2025
OLVG, Orthopedic Surgery Department, Amsterdam, the Netherlands.
Background: Evidence supporting surgery in elderly patients with distal radius fractures is limited, but displaced fractures may benefit from surgery. This study aimed to determine whether casting is noninferior to surgery for patients aged 65 years or older with substantially displaced intra-articular (AO type C) distal radius fractures.
Methods: This multicenter randomized controlled noninferiority trial included 138 patients (mean age 76 years, SD 6.
J Cardiovasc Magn Reson
September 2025
Department of Magnetic Resonance Imaging, Fuwai Hospital and National Center for Cardiovascular Diseases, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100037, China; Key Laboratory of Cardiovascular Imaging, Chinese Academy of Medical Sciences, Beijing 100730, China.
Background: Conventional cardiac magnetic resonance (CMR) examinations require patients to repeatedly hold their breath, which can reduce examination efficiency and pose challenges for patients unable to do so. This study aimed to demonstrate the feasibility and effectiveness of a full free-breathing CMR protocol in clinical practice.
Methods: Patients prospectively enrolled in this study underwent a full free-breathing CMR exam on a 3T scanner between June 1 and June 30, 2024.