Effects of simulated lateral canals on the accuracy of measurements by an electronic apex locator.

J Can Dent Assoc

Gazi University, Faculty of Dentistry, Department of Operative Dentistry and Endodontics, 82.St. Emek, 06510 Ankara, Turkey.

Published: November 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Accurate determination of the apical terminus plays a significant role in the success of root canal therapy, but accuracy may be affected by the presence of accessory canals.

Objective: To evaluate the accuracy of a ratio-based electronic apex locator for roots with simulated lateral canals.

Methods: Forty-two single-rooted human teeth were randomly divided into 2 groups. For each tooth, the root canal was prepared to the visually determined working length, and the working length was then measured with the Justy II electronic apex locator. Simulated lateral canals (of 2 different diameters) were then prepared at 3 mm (group A) or 6 mm (group B), and the working lengths were measured again with the same instrument. The measurements were analyzed by one-way analysis of variance.

Results: For both groups, there were no significant changes in working length after the creation of simulated canals (p > 0.05).

Conclusion: Measurements obtained with the ratio-based electronic apex locator were not affected by the preparation of simulated lateral canals, and the instrument was able to accurately determine the location of the tooth apex.

Download full-text PDF

Source

Publication Analysis

Top Keywords

simulated lateral
16
electronic apex
16
apex locator
16
lateral canals
12
working length
12
root canal
8
ratio-based electronic
8
apex
5
effects simulated
4
lateral
4

Similar Publications

Purpose: The purposes of this study were threefold: (1) to evaluate the influence of femoral antecurvature on coronal alignment changes following supracondylar femoral derotational osteotomy (FDO); (2) to investigate the combined effects of derotation angle and osteotomy orientation in relation to femoral antecurvature and (3) to propose a practical strategy for minimising valgus deviation after FDO based sagittal femoral bowing.

Materials And Methods: Sixty-six cadaveric femoral computed tomography (CT) scans were analysed using three-dimensional (3D) simulation. Femurs were classified into three groups based on the degree of antecurvature using the distal diaphyseal angle (DDA).

View Article and Find Full Text PDF

Tunable cell separation using a thermo-responsive deterministic lateral displacement device.

Lab Chip

September 2025

Institute of Integrated Research, Institute of Science Tokyo, R2-9, 4259 Nagatsuta-cho, Midoriku, Yokohama, Kanagawa 226-8501, Japan.

Tunability in isolating target cells of varying sizes from complex heterogeneous samples is essential for biomedical research and diagnostics. However, conventional deterministic lateral displacement (DLD) systems lack flexibility due to their fixed critical diameters (). Here, we present a thermo-responsive DLD micropillar array that enables tunable cell separation by dynamically modulating through temperature control.

View Article and Find Full Text PDF

Voltage-dependence gating of ion channels underlies numerous physiological and pathophysiological processes, and disruption of normal voltage gating is the cause of many channelopathies. Here, long timescale atomistic simulations were performed to directly probe voltage-induced gating transitions of the big potassium (BK) channels, where the voltage sensor domain (VSD) movement has been suggested to be distinct from that of canonical Kv channels but remains poorly understood. Using a Core-MT construct without the gating ring, multiple voltage activation transitions were observed at 750 mV, allowing detailed analysis of the activated state of BK VSD and key mechanistic features.

View Article and Find Full Text PDF

Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements based on calibration factors determined .

View Article and Find Full Text PDF

Microplastics, tiny fragments resulting from the degradation of plastic waste, are abundant in water, air, and soil and are currently recognized as a global environmental problem. There is also growing evidence that nanosized microplastics (nanoplastics) can be hazardous to living species. Unlike most experimental methods, computer modeling is particularly well suited to studying the effects of such nanoplastics.

View Article and Find Full Text PDF