Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To report clinical results of non-Descemet stripping automated endothelial keratoplasty (nDSAEK) to treat graft failure after penetrating keratoplasty.

Methods: It was a retrospective case series study. Five cases of grafts failure after penetrating keratoplasty (PKP) were enrolled in this study. All patients had a cloudy and swollen grafts, which thicker than 620 µm, and had foreign body sensation, vision decrease. Of this 5 cases, 4 of them are pseudophakic eye, 1 is aphakic eye. One patient had previous vitrectomy, and 3 of them had one time history of PKP, 2 of them had twice PKP treatment. All cases were treated by nDSAEK, the nDSAEK grafts were prepared as a 200 µm thickness and 8.00 to 8.75 mm in diameter by using hand or femtosecond laser assisted methods. The graft was inserted by forceps or suture pulling method through a 5.00 mm scleral tunel incision.

Results: One graft dislocated at 1day postoperation, and was reattached by rebuble. All grafts keep clear during 8 - 28 months follow up period, and no immune rejection episodes were noted. The endothelial density were 865 to 2410/mm(2). Postoperative best corrected vision (pBCVA) are better or equal to previous BCVA after pkp.

Conclusion: nDSAEK appears a good alternative surgical method for patients of grafts failure after pkp, especially for high risk patients of immune rejection.

Download full-text PDF

Source

Publication Analysis

Top Keywords

failure penetrating
12
stripping automated
8
automated endothelial
8
endothelial keratoplasty
8
graft failure
8
grafts failure
8
immune rejection
8
grafts
5
[non-descemet stripping
4
graft
4

Similar Publications

Background: The global penetration of mobile phones has offered novel opportunities for communicating health-related information to individuals. A low-cost system that facilitates autonomous communication with individuals via mobile phones holds potential for expanding the reach of health messaging in settings with human resource and infrastructure limitations.

Objective: We sought to design a flexible, low-code system using open-source software that could be adapted to different contexts and technical environments and accommodate a wide range of automation needs.

View Article and Find Full Text PDF

A KIM-1 targeted ONOO-sensitive NIR fluorescence probe for enhanced acute kidney injury diagnosis.

Talanta

September 2025

School of Pharmaceutical Science, Zhengzhou University, Zhengzhou, 450001, China; Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases, Zhengzhou, 450001, China. Electronic address:

Acute kidney injury (AKI) is a swiftly advancing condition that may result in kidney failure and pose a significant threat to life. Therefore, diagnosis of AKI is crucial for treating AKI and preventing the worsening of the condition. We developed a near-infrared fluorescent probe, CyO@CD-Ser, designed for the diagnosis of AKI.

View Article and Find Full Text PDF

Purpose: Crohn's disease (CD) is characterized by enteric inflammation, often resulting in strictures and penetrating complications, which may alter patient management prior to the initiation of biologic therapy. Our aim is to assess the frequency of missed stricturing and internal penetrating complications in CD patients on computed tomography enterography (CTE) and magnetic resonance enterography (MRE) performed prior to anti-TNF therapy.

Methods: We retrospectively reviewed patients from two tertiary centers who underwent CTE\MRE within six months before starting anti-TNF therapy.

View Article and Find Full Text PDF

Plasticity Mechanisms in Nanostructured Cubic Boron Nitride: Internal Defects and Amorphous Layers.

ACS Appl Mater Interfaces

September 2025

School of Materials Science and Engineering, Beihang University, Beijing 100191, P. R. China.

Nanostructured cubic boron nitride (NS-cBN) has attracted significant attention due to its high hardness and excellent thermal stability, yet a systematic strategy to balance strength and toughness through atomically structural design remains elusive. Here, we integrate plasticity theory with large-scale atomistic simulations to elucidate the size-dependent roles of internal defects, i.e.

View Article and Find Full Text PDF

Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.

View Article and Find Full Text PDF