Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Transendocardial gene delivery may expose patients to the risk of pericardial perfusion due to excessive needle injections. This study investigated the feasibility and safety of transendocardial gene injection using a newly developed multifunctional intracardiac echocardiography catheter.
Methods: This new system integrated intracardiac echocardiography, a retractable 29-G needle, and other accessories into a single catheter (10F) that could be delivered into the left ventricle via a retrograde aortic approach. In three canines, the catheter was used to inject 0.2 ml of Evan's blue; six canines received myocardial injections of plasmid containing the EGFP transgene. In addition, two canines received transendocardial injections of a pAdTrace-bFGF plasmid. All canines receiving gene delivery were sacrificed after 3 days. The hearts were harvested for gross, histological examination and gene expression assessment.
Results: This catheter provided visual guidance for accurate needle-tip positioning within the target myocardium; the needle position was subsequently confirmed by microbubble infusion. No animal had pericardial effusion or sustained ventricular arrhythmia. Tissue staining showed well-demarcated margins within the target myocardium. In animals injected with pEGFP-N1, confocal microscopy demonstrated successful gene expression. In zones where pAdTrace-bFGF was injected, immunohistochemistry also showed positive staining. Compared to normal tissue (0.38±0.04), RT-PCR showed high levels of bFGF expression (0.63±0.02) in the target area (P<0.01).
Conclusions: Transendocardial gene injection using a multifunctional intracardiac echocardiography catheter is feasible and could improve procedure-related safety which may provide a new strategy for transgene delivery in future.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2011.09.011 | DOI Listing |