Background And Objectives: A new test (Dr. KSU H1N1 RT-PCR kit) was recently developed to provide a less expensive alternative to real-time reverse transcriptase-polymerase chain reaction (RT-PCR). We report the findings of a validation study designed to assess the diagnostic accuracy, including sensitivity and specificity, of the new kit, as compared to real-time RT-PCR.

Design And Setting: Cross-sectional validation study conducted from 18-22 November 2009 at a primary care clinic for H1N1 at a tertiary care teaching hospital in Riyadh.

Patients And Methods: Nasopharyngeal swab samples and data on socio-demographic characteristics and symptoms were collected from 186 patients. Swab samples were sent to the laboratory for testing with both real-time RT-PCR and the new Dr. KSU H1N1 RT-PCR kit. We measured the sensitivity and specificity of the new test across the entire sample size and investigated how these values were affected by patient socio-demographic characteristics and symptoms.

Results: The outcomes of the two tests were highly correlated (kappa=0.85; P<.0001). The sensitivity and specificity of the new test were 99.11% and 83.78%, respectively. The sensitivity of the new test was affected only minimally (96%-100%) by patient characteristics and number of symptoms. On the other hand, the specificity of the new test varied depending on how soon patients were tested after onset of symptoms (100% specificity when swabs were taken on the first day of the symptoms, decreasing to 75% when swabs were taken on or after the third day). The specificity of the new test also increased with increasing body temperature.

Conclusion: The new test seems to provide a cost-effective alternative to real-time RT-PCR for diagnosing H1N1 influenza. However, further testing may be needed to verify the efficacy of the test in different settings and communities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3156509PMC
http://dx.doi.org/10.4103/0256-4947.83212DOI Listing

Publication Analysis

Top Keywords

validation study
12
sensitivity specificity
12
ksu h1n1
12
h1n1 rt-pcr
12
rt-pcr kit
12
real-time rt-pcr
8
swab samples
8
socio-demographic characteristics
8
rt-pcr
6
h1n1
5

Similar Publications

Background And Aims: Cholangiopathies, including primary sclerosing cholangitis (PSC), primary biliary cholangitis (PBC), and post-COVID-19 cholangiopathy (PCC), involve chronic cholangiocyte injury, senescence, epithelial-stromal crosstalk, and progressive fibrosis. However, effective in vitro models to capture these interactions are limited. Here, we present a scaffold-free 3D multilineage spheroid model, composed of hepatocyte-like cells (HepG2), cholangiocytes (H69), and hepatic stellate cells (LX-2), designed to recapitulate early fibrogenic responses driven by senescent cholangiocytes.

View Article and Find Full Text PDF

Introduction: Intrinsic foot muscles and the plantar fascia are crucial for foot health, which diminishes with age and conditions such as chronic plantar fasciitis (PF). Ultrasound (US) is an accessible and cost-effective method for evaluating these structures. This study aims to assess the repeatability, reliability, and validity of plantar fascia thickness and flexor digitorum brevis (FDB) muscle measurements using US compared with MRI in individuals with and without PF.

View Article and Find Full Text PDF

Validation of a video-based tool to assess risk perception both objectively and subjectively in pedestrians.

J Safety Res

September 2025

Universidad Europea del Atlántico, Santander, Spain; Universidad Internacional Iberoamericana, Campeche, México.

Introduction: Road crashes involving pedestrians are still a relevant cause of death and injury in Spain. Risk perception in pedestrians has been proposed as one of the main predictors of risky behaviors and crash-related events. The current research aimed to validate a video-based tool to assess risk perception in pedestrians, considering both the subjective way (self-report) and the objective way (skin conductance level and response).

View Article and Find Full Text PDF

Validating traffic simulation for crash risk assessment using field crash data.

J Safety Res

September 2025

National Technical University of Athens, Department of Transportation Planning and Engineering, 5 Iroon Polytechniou St., GR-15773 Athens, Greece.

Introduction: Assessing safety using traffic simulation is becoming increasingly feasible with advancements in methodological frameworks and tools, emphasizing the critical importance of accuracy and reliability. This study aims to bridge the gap between simulation models and real-world safety observations, contributing to the advancement of more robust safety assessment methodologies. It presents a comprehensive comparative analysis of traffic safety metrics derived from both simulated and real-world data, employing clustering technique to identify safety patterns.

View Article and Find Full Text PDF