Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Accurate measurements of ocular biometry and objective refraction are of vital importance to research laboratories working in the area of refractive error development and oculomotor function. A number of commercially available instruments can provide these measurements, and are used in both their intended modes, and with modifications to increase their research utility. A limitation that exists currently is the inability to conduct simultaneous measurements of refractive error or accommodation response, and the axial length of the same eye. In this technical note we provide details of a method to adapt the Zeiss IOLMaster and the Shin-Nippon SRW-5000 infrared optometer to simultaneously measure refraction and axial length.

Methods: The optical modification used to combine the measurement paths of the IOLMaster and SRW-5000 instruments consists of a narrow band-pass filter, and optical relay to extend the working distance of the IOLMaster, and an electronic system to provide synchronisation between the IOLMaster and the SRW-5000 continuous accommodation recording system. The optical modification was tested on model eyes, and on a cohort of 20 human eyes. The combined system was then used to measure accommodation response and axial length simultaneously in a single participant.

Results: Inclusion of the optical modification in the IOLMaster pathway induced a 0.004 mm shift in the average measurement of a calibration eye, and an average difference of 0.001 mm for a cohort of human eyes. For the SRW-5000, inclusion of the modified optics induced a +0.15 D shift in the spherical component of refraction measurements made on a model eye, and an average shift of +0.12 D in the spherical component of measurements made on a cohort of human eyes. Simultaneous measurement of accommodation response and axial length in a single participant revealed that a change in stimulus vergence from 0 to 5 D caused an average accommodation response of 3.89 D, and an average transient axial length change of 0.059 mm.

Conclusions: The system described provides a useful method of achieving simultaneous measurements of axial length, objective refraction and accommodation response in a human eye.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-1313.2010.00794.xDOI Listing

Publication Analysis

Top Keywords

accommodation response
24
axial length
24
response axial
16
objective refraction
12
optical modification
12
cohort human
12
human eyes
12
simultaneous measurement
8
refraction accommodation
8
human eye
8

Similar Publications

The bacterial DNA damage (SOS) response promotes DNA repair, DNA damage tolerance, and survival in the setting of genotoxic stress, including stress induced by antibiotics. In , translesion DNA synthesis can be fulfilled by Y-family DNA polymerases, including DNA polymerase IV (DinB). DinB features a more open active site and lacks proofreading ability, promoting error-prone replication.

View Article and Find Full Text PDF

Unlabelled: The diagnostic potential of computer accommodography remains insufficiently studied. At the same time, accommodative and refractive disorders are extremely common today among the youth.

Objective: This study investigated objective accommodative parameters using computer accommodography in samples of individuals aged 17-19 and 20-23 years with and without a diagnosis of myopia.

View Article and Find Full Text PDF

Chronic myelomonocytic leukemia (CMML) is an aggressive hematologic neoplasm characterized by an expansion of CD123 monocytes and plasmacytoid dendritic cells (pDCs). pDC bone marrow clusters in CMML have been associated with higher rates of acute myeloid leukemia transformation. We evaluated tagraxofusp, a CD123-targeted therapy, in a phase 1/2 trial for patients with CMML.

View Article and Find Full Text PDF

Introduction: Emergency shelters offer temporary accommodation to people deprived of housing. Service restriction is the practice of limiting or denying access to emergency shelters in response to behaviours deemed harmful to staff, community members or other clients. This community-based qualitative study describes the characteristics, healthcare utilisation and morbidity of people experiencing service restrictions.

View Article and Find Full Text PDF

Background And Objective: Sacituzumab govitecan, an anti-trophoblast cell surface antigen 2 (TROP2) antibody-drug conjugate, has been approved by both the US Food and Drug Administration and European Medicines Agency for patients with metastatic triple-negative breast cancer who have received two or more prior systemic therapies, including at least one of them for advanced disease. Although TROP2 evaluation is not required for patient selection, survival data from the ASCENT trial show improved response rates in patients with high TROP2 expression by immunohistochemistry. However, there is no standardized testing assay for these patients.

View Article and Find Full Text PDF