Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Evidence is accumulating that radiotherapy of non-small cell lung cancer patients can be optimized by escalating the tumour dose until the normal tissue tolerances are met. To further improve the therapeutic ratio between tumour control probability and the risk of normal tissue complications, we firstly need to exploit inter patient variation. This variation arises, e.g. from differences in tumour shape and size, lung function and genetic factors. Secondly improvement is achieved by taking into account intra-tumour and intra-organ heterogeneity derived from molecular and functional imaging. Additional radiation dose must be delivered to those parts of the tumour that need it the most, e.g. because of increased radio-resistance or reduced therapeutic drug uptake, and away from regions inside the lung that are most prone to complication. As the delivery of these treatments plans is very sensitive for geometrical uncertainties, probabilistic treatment planning is needed to generate robust treatment plans. The administration of these complicated dose distributions requires a quality assurance procedure that can evaluate the treatment delivery and, if necessary, adapt the treatment plan during radiotherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2010.07.001DOI Listing

Publication Analysis

Top Keywords

intra-tumour intra-organ
8
intra-organ heterogeneity
8
non-small cell
8
cell lung
8
lung cancer
8
normal tissue
8
treatment
5
estro breur
4
breur lecture
4
lecture 2009
4

Similar Publications

3D calculation of absorbed dose for 131I-targeted radiotherapy: a Monte Carlo study.

Radiat Prot Dosimetry

July 2012

Department of Radiomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.

Various methods, such as those developed by the Medical Internal Radiation Dosimetry (MIRD) Committee of the Society of Nuclear Medicine or employing dose point kernels, have been applied to the radiation dosimetry of (131)I radionuclide therapy. However, studies have not shown a strong relationship between tumour absorbed dose and its overall therapeutic response, probably due in part to inaccuracies in activity and dose estimation. In the current study, the GATE Monte Carlo computer code was used to facilitate voxel-level radiation dosimetry for organ activities measured in an (131)I-treated thyroid cancer patient.

View Article and Find Full Text PDF

Evidence is accumulating that radiotherapy of non-small cell lung cancer patients can be optimized by escalating the tumour dose until the normal tissue tolerances are met. To further improve the therapeutic ratio between tumour control probability and the risk of normal tissue complications, we firstly need to exploit inter patient variation. This variation arises, e.

View Article and Find Full Text PDF