A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Rapid detection of Pseudomonas aeruginosa in mouse feces by colorimetric loop-mediated isothermal amplification. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A colorimetric loop-mediated isothermal amplification (LAMP) assay with hydroxy naphthol blue was designed to amplify a region in the outer membrane lipoprotein (oprL) gene of Pseudomonas aeruginosa. The LAMP assay showed 100% specificity for the serogroup and other bacteria, and the sensitivity was 10-fold higher than that of the PCR assays. The LAMP assay could detect P. aeruginosa inoculated in mouse feces at 130 colony-forming units (CFU)/0.1g feces (3.25 CFU/reaction). The assay was completed within 2h from DNA extraction. In a field trial, the LAMP assay revealed that none of the 27 samples was obtained from 2 specific pathogen-free (SPF) mouse facilities that were monitoring infection with P. aeruginosa; 1 out of 12 samples from an SPF mouse facility that was not monitoring infection with P. aeruginosa and 2 out of 7 samples from a conventional mouse facility were positive for P. aeruginosa. In contrast, P. aeruginosa was not detected in any of the samples by a conventional culture assay. Thus, this colorimetric LAMP assay is a simple and rapid method for P. aeruginosa detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mimet.2010.03.008DOI Listing

Publication Analysis

Top Keywords

lamp assay
20
aeruginosa
8
pseudomonas aeruginosa
8
mouse feces
8
colorimetric loop-mediated
8
loop-mediated isothermal
8
isothermal amplification
8
spf mouse
8
monitoring infection
8
infection aeruginosa
8

Similar Publications