A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Most occurrences of large patent ductus arteriosus (PDAs) of > or =10 mm have been surgically closed, and transcatheter closure of these large PDAs was only reported in a few case reports. The present study reviewed our experience in transcatheter closure of such large PDAs with a Chinese self-expandable occluder, which is similar to but much cheaper than the Amplatzer occluder. From July 2000 to January 2008, 23 patients underwent transcatheter closure of large PDA > or =10 mm with this kind of occluder. The mean (SD) age of the patients was 38.0 (15.6) years (range 18-75 years). Radiographs of the chest, electrocardiograms, and echocardiograms were used for follow-up evaluation of the treatment within 1 day, 1 month, 6 months, and then every year after successful closure. The mean (SD) angiographic PDA diameter was 12.8 (2.6) mm (range 10-18 mm) and the mean occluder diameter was 18.0 (2.9) mm (range 16-22 mm). The occluders were delivered successfully and closed the PDA completely in 19 out of the 23 patients. Pulmonary arterial pressures decreased significantly after occlusion in patients with successful treatment: 67.3 (24.7) mmHg (range 29-122 mmHg) before occlusion and 42.3 (22.0) mmHg (range 19-98 mmHg) immediately after the procedure. Radiographs of the chest and echocardiograms showed that the diameters of the left atrium, left ventricle, and the main pulmonary artery decreased, and the ejection fraction (EF) increased at a mean (SD) follow-up of 36.3 (18.7) months (range 6-72 months). No severe complication occurred. The immediate and long-term outcomes suggested that transcatheter closure of PDAs with the native PDA occluder is a safe and effective treatment for adults with large PDA > or =10 mm.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-009-1150-5DOI Listing

Publication Analysis

Top Keywords

transcatheter closure
20
closure large
16
large patent
8
patent ductus
8
ductus arteriosus
8
self-expandable occluder
8
large pdas
8
large pda
8
pda =10
8
radiographs chest
8