A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Separation of 2-aminobenzamide labeled glycans using hydrophilic interaction chromatography columns packed with 1.7 microm sorbent. | LitMetric

Separation of 2-aminobenzamide labeled glycans using hydrophilic interaction chromatography columns packed with 1.7 microm sorbent.

J Chromatogr B Analyt Technol Biomed Life Sci

Biopharmaceutical Sciences, Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.

Published: February 2010


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Separation by hydrophilic interaction chromatography (HILIC) with fluorescence detection utilizing a sub-2 microm glycan column for the separation of 2-aminobenzamide (2-AB) labeled N-linked glycans is described. The HILIC column packed with a 1.7 microm amide sorbent improves the peak capacity compared to a 3.0 microm HILIC column by a similar degree as observed in reversed-phase ultra-performance liquid chromatography (RP-UPLC). The results indicated that the optimal peak capacity was achieved at flow rate 0.2-0.5 mL/min. HILIC method transfer guidelines were shown to further enhance the resolution of glycans by changing initial gradient conditions, flow rate, column temperature, and different column lengths. Additionally, excellent resolution can be achieved in the separation of 2-AB labeled glycans released from fetuin, RNase B, and human IgG with a rapid analysis time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2009.12.013DOI Listing

Publication Analysis

Top Keywords

separation 2-aminobenzamide
8
labeled glycans
8
hydrophilic interaction
8
interaction chromatography
8
packed microm
8
2-ab labeled
8
hilic column
8
peak capacity
8
flow rate
8
column
5

Similar Publications